KP-46WT520/51WS520/57WS520
KP-46WT520/51WS520/57WS520
8
Display of Standby/Timer LED Flash Count
STAND BY Indicator
TIMER Indicator
Diagnostic items
Flash count
Lamp OFF 3 sec.
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
+B Overcurrent
2 times
Low +B Overvoltage
3 times
Vert. Deflection Stopped
4 times
White Balance Failure
5 times
Low +B OCP/OVP
6 times
Horiz. Deflection Stopped
7 times
Audio Protection
8 times
Zero Crossing Detector
9 times
HV Protection
10 times
Release of TIMER STAND BY indicator blinking
The TIMER/STANDBY indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the power.
Self-Diagnosis Screen Displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen
disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated or
not) in order to allow confi rmation.
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
Display
Channel 5
Sound Volume*
_
Power ON
*Note that this differs from entering the service mode (sound volume + )
Numeral “0”
means that no fault was detected.
Numeral “1”
means a fault was detected one
time only.
SELF DIAGNOSIS
2:
+B
OCP
0
3:
+B
OVP
0
4:
VSTOP
0
5:
AKB
1
6:
LOWB
0
7:
H-STOP
0
8:
AUDIO
0
9:
ZCD
0
10:
HV
PROT
0
101:
WDT
24
Self-Diagnosis Screen Display
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the results
display to “ 0 ”.
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
Method of Clearing Results Display
1. Power off (Set to the stand by mode.)
2. Display
Channel 5
Sound Volume +
Power ON (Service Mode)
3. Channel 8
ENTER (Test reset = Factory preset condition)
Method of Ending Self Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
Summary of Contents for Hi-Scan KP-51WS520
Page 17: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 17 WIRE DRESSING 46 Cabinet 46 HB ...
Page 20: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 20 HV Wire HV wire HV Wire HV wire ...
Page 25: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 25 DY Sub DY B DY G DY Excess wire ...
Page 29: ...KP 46WT520 51WS520 57WS520 KP 46WT520 51WS520 57WS520 29 AR Sensor Excess Wire AR Sensor ...