4-5. BLUE OFFSET ADJUSTMENT
1. Receive the all black (1080i, component) signal with VIDEO 5 input,
and set PICTURE to maximum.
2. Connect an oscilloscope between CN5 7 pin (B) on the (A Board) and
ground.
3. Set in the service mode and select the category “DEF2-SLIN”.
4. Adjust “3 SLIN” so that the waveform level is 2.20 ± 0.05Vpp.
5. After completing the adjustments, write the data into memory by
pressing “MUTING”
Æ
“ENTER” on the remote commander.
6. Receive the RF signal and change the wide screen mode to “Wide
Zoom”. Copy the same data to “DEF2-SLIN”.
Reference Pulse
2.20 ± 0.05 Vp-p
GND
16.7ms