3-2 (E)
HDCU-F950 IMM
Use the shorter nose end.
Shock absorber
Handle
When the Optical Connector Cleaner
(Commercially Available) is not Available:
Tools required
.
Alignment sleeve remover HC-001
(for female connector)
Sony P/N : J-6480-010-A
n
Insert the shorter nose end when removing/installing the
alignment sleeve.
Grasp not the shock absorber portion of the remover but
the handle in use.
.
Cotton swabs (commercially available)
n
Use a cotton swab whose diameter is about 4 mm.
If a cotton swab whose diameter exceeds 5 mm is used,
the cotton swab cannot be inserted into the end of the
connector and the tip of the optical contact cannot be
cleaned.
.
Alcohol (commercially available)
Cleaning
[Male connector]
Clean the tip of the white optical contacts by a cotton swab
moistened with alcohol.
[Female connector]
The optical contacts for female connector are in an unex-
posed state. In cleaning, it is necessary to be exposed by
removing the alignment sleeve in advance. Proceed as
follows.
1.
Insert the alignment sleeve remover into the alignment
sleeve in the straight line and turn it clockwise.
Optical contacts (white)
Alignment sleeve
Alignment sleeve remover