17
Adjustments and
Settings for Shooting
Adjusting the Black Balance and White
Balance
In order to maintain high picture quality, it is necessary to set
the black balance and white balance appropriately for the
conditions.
Black balance adjustment
The black balance needs adjustment in situations like the
following:
• The first time the camera is used
• When the camera is used after a long period of disuse
• When the surrounding temperature changes greatly
• When the gain value is changed using the setup menus
Normally, there is no need to adjust the black balance every
time the camera is turned on.
White balance adjustment
Always readjust the white balance when lighting conditions
change.
About the viewfinder screen
After the process of adjusting the black balance or white
balance begins, messages about the progress and results of
the adjustment will be displayed on the viewfinder screen.
Adjusted values set through automatic adjustment, and other
settings, are stored in the camera’s memory and preserved
even when the camera power is turned off.
Adjusting the black balance
Execute auto black balance (ABB) adjustment from the MSU
or RCP.
Automatic adjustment of black balance begins.
In automatic adjustment of black balance, both the black set
and black balance are adjusted.
During adjustment, a message like the one in the figure below
will be displayed on the viewfinder screen.
When the adjustment process is completed, the message
“ABB : OK” will be displayed. The adjusted value is
automatically stored in memory.
• During black balance adjustment, the iris will be
automatically closed.
• During black balance adjustment, the gain switching circuit
will work automatically, and the viewfinder screen will flicker
several times. This is not a malfunction.
• If not in a completely shielded environment, attach the lens
cap and then execute auto black balance (ABB) adjustment.
When automatic black balance adjustment fails
If the automatic black balance adjustment process does not
end successfully, the error message “ABB : NG” will be
displayed on the viewfinder screen for approximately three
seconds.
If this error message is displayed, try black balance
adjustment again.
If the error message continues to be displayed after several
attempts, the camera requires internal inspection.
About black balance memory
The black balance values stored in memory will be preserved
even when the camera power is turned off.
Adjusting the white balance
1
Execute auto white balance (AWB) adjustment from
the MSU or RCP.
2
Select the filter setting according to the lighting
conditions.
To select the ND filter
Press the ND filter select button while holding the FILTER
LOCAL button depressed.
Each press of the select button switches the available ND
filters (clear, 1/4 ND, 1/16 ND) in sequence.
To select the CC (color temperature conversion) filter
Press the CC filter select button while holding the FILTER
LOCAL button depressed.
Each press of the select button switches the available CC
filters (3200K, 4300K, 6300K) in sequence.
Note
Notes
ABB:EXECUTING
ND filter
Color temperature conversion
filter
1
Clear
A
3200K (clear)
FILTER LOCAL button
ND filter select button
CC filter select button