6-103
HVR-S270J/S270U/S270N/S270E/S270P/S270C
6-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
3-1-1.
Precautions on Adjusting
Note:
Before performing the adjustment, check the data of page:
0, address: 10 is “00”. If not, select page: 0, address: 00,
and set data “00”.
1) The adjustments of this unit are performed in the VTR mode
(VCR mode) or camera mode (CAMERA mode).
AUDIO OUT
VIDEO OUT
Pr/Cr
y
L
TC
OUT
Pb/Cb
R
S VIDEO
LANC
AUDIO INPUT3
AUDIO INPUT4
HD/SD
SDI OUT
DC
IN
12V
DC
OUT
12V
S Video
S VIDEO
jack
Pr/Cr
Pb/Cb
Y
VIDEO system adjustment
(COMPONENT OUT)
LANC jack
VIDEO OUT jack
Pr/Cr jack
Pb/Cb jack
Y jack
Video
VIDEO system adjustment
(S VIDEO, VIDEO)
1
20
Terminated
75
Ω
20
1
CN1018
VC-513 board
Osilloscope
CPC-13 jig
(J-6082-443-A)
Adjustment remote commander
RM-95
(J-6082-053-B)
NEW LANC JIG
(J-6082-565-A)
LANC cable
(J-6082-442-A)
DC IN 12V jack
Terminated
75
Ω
Osilloscope
Circular connector
(PF, XLR4P)
(1-783-189-11)
Regulated power supply
(14.4
±
0.2 Vdc, 4 A or more)
Fig. 6-3-1
3-1-3.
Connecting the Equipment
Connect the measuring instruments as shown in Fig. 6-3-1, and
perform the adjustments.
3-1-2.
Adjusting Connectors
The measuring point of the playback RF signal is CN1018 of VC-
513 board. Connect the measuring instruments via the CPC-13 jig
(J-6082-443-A). Refer to “MECHANISM SECTION ADJUST-
MENT” for the measuring method. The following table lists the
test pin numbers of CPC-13 jig, and the pin numbers and signal
names of CN1018.
Pin No.
Signal Name
Pin No.
Signal Name
1 (20)
REG_GND
11 (10) EEP_SO_C
2 (19)
RF_MON
12 (9)
EEP_SO_S
3 (18)
REG_GND
13 (8)
EEP_SCK_C
4 (17)
SWP
14 (7)
EEP_SCK_S
5 (16)
FRRV
15 (6)
D_2.8V
6 (15)
REG_GND
16 (5)
MD2_C
7 (14)
REG_GND
17 (4)
MD2
8 (13)
REG_GND
18 (3)
XCS_MC_FLASH_C
9 (12)
EEP_SI_C
19 (2)
XCS_MC_FLASH
10 (11) EEP_SI_S
20 (1)
XSYS_RST
Note:
The pin number in ( ) is test terminal number of CN1018
on the VC-513 board.
Table 6-3-1