![Sony HANDYCAM HVR-S270P Service Manual Download Page 302](http://html.mh-extra.com/html/sony/handycam-hvr-s270p/handycam-hvr-s270p_service-manual_404915302.webp)
6-68
HVR-S270J/S270U/S270N/S270E/S270P/S270C
2-4. Flange Back Check (ND4)
(Using the flange back adjustment jig)
Subject
Flange back adjustment jig
(Illuminance: approx. 400
±
50 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
(Note 2)
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 4
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
Set the ND FILTER to “4”.
2
0
01
01
3
6
99
Check the data is “03”.
4
0
10
01
5
6
2C
01
(16)
6
6
40
01
(16)
7
0
10
00
8
6
41
01
9
6
4D
40
10
Shoot the chart with the
zoom TELE end.
11
0
10
01
12
6
2C
02
(16)
13
Check that the lens is
focused.
14
Shoot the chart with the
zoom WIDE end.
15
Check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
(16)
2
6
40
00
(16)
3
0
10
00
4
6
41
00
5
6
4D
00
6
0
10
01
7
6
2C
00
(16)
8
0
10
00
9
0
01
00