6-46
HVR-S270J/S270U/S270N/S270E/S270P/S270C
15. Color Reproduction Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
A8 to B7
Specified Value
Data of page: 6 address: 0C is “00”
Note 1:
Perform “Linear Matrix Adjustment” and “Auto White
Balance Standard Data Input (ND1 (CLR))” before this
adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 1
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
99
Check the data is “00”.
3
6
02
Check the data is “00”.
4
6
9B
Check the bit value of bit2 is
“0”. (Note 4)
5
6
9B
Check the bit value of bit3 is
“0”. (Note 4)
6
6
07
Check the data is “04”.
7
0
10
01
8
6
07
Check the data is “04”.
(16)
9
0
10
00
10
6
61
01
11
Wait for 3 seconds.
12
0
10
01
13
6
40
01
(16)
14
0
10
00
15
6
41
01
16
6
C9
10
17
6
CA
04
18
6
D0
34
19
6
01
61
Press PAUSE (Write) button.
(Note 5)
20
6
02
Check the data changes to
“01”.
21
6
0C
Check the data is “00”.
Note 4:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 5:
The adjustment data will be automatically input to page:
6F, address: A8 to B7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
C9
00
3
6
CA
00
4
0
10
01
5
6
40
00
(16)
6
0
10
00
7
6
41
00
8
6
61
00
9
Wait for 3 seconds.
10
0
01
00