
6-24
DSC-P100/P120
5.
Data Save Error
Fig. 6-1-52
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
• Data writing to the flash memory failed.
• Connection is faulty.
• Power supply is not installed correctly.
Remedy
• On the SEUS Operation screen,
[Set]
the data
to the pages and addresses displayed in the
message, and
[Save]
them. (Cancel manu-
ally the data setting during adjustment.)
• Check the connection.
• Install the power supply correctly.
1-6-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not
operate normally.
In this case, the
[Release Data Setting]
button is displayed in
“red” on the screen as shown in Fig. 6-1-53, 54 and 55. Click the
[Release Data Setting]
button to cancel the data setting. When
the data setting is cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred, the
[Release Data
Setting]
button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Video System Adjustment screen
Fig. 6-1-53
Camera System Adjustment screen
Fig. 6-1-54
LCD System Adjustment screen
Fig. 6-1-55
How to cancel the
data setting during
adjustment is
display here.