6-33
DCR-DVD100/DVD100E
4. PSIG GLAY Adjustment (PD-188 board)
Set the PSIG signal level to an appropriate level.
Mode
MOVIE (
)
Subject
Arbitrary
Measurement Point
Pin
5
of CN1003 of VC-307 board
(PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
B
Adjustment Address
66
Specified Value
A = 5.00
±
0.05V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
B
66
Change the data and set the PSIG
signal level (A) to the specified
value. (The data should be “00”
to “7F”.)
3
B
66
Press PAUSE button.
4
0
01
00
Set the data.
5. Contrast Adjustment (PD-188 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
MOVIE (
)
Subject
Arbitrary
Measurement Point
Pin
3
of CN1003 of VC-307 board
(PANEL VG)
Measuring Instrument
Oscilloscope
Adjustment Page
B
Adjustment Address
69
Specified Value
A = 2.60
±
0.05V (NTSC)
A = 2.58
±
0.05V (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
B
69
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value. (The data should
be “00” to “7F”.)
3
B
69
Press PAUSE button.
4
0
01
00
Set the data.
5
Check that the specified value of
“Bright Adjustment” is satisfied. If
not, perform “Bright Adjustment”.
Fig. 6-1-21.
Fig. 6-1-20.
A
2H
100 IRE
Pedestal
A
2H