6-25
DCR-DVD100/DVD100E
15. White Balance Check
Subject
Clear chart (All white frame) (Note2)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Vectorscope
Specified Value
Fig. 6-1-13. A to B
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Perform “12. Picture Frame Setting (All White Frame)”.
Switch setting:
1)
MODE ............................................................. MOVIE (
)
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not covered
with either filter.
2
6
48
02
Set the data.
3
6
01
0F
Set the data, and press PAUSE
button.
4
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-13. A.
5
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
6
Place the C14 filter on the lens.
7
6
01
3F
Set the data, and press PAUSE
button.
8
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-13. B.
9
Remove the C14 filter.
LV data check
10
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
11
6
01
00
Set the data, and press PAUSE
button.
12
0
03
06
Set the data.
13
1
Check that the display data
(Note3) satisfies the specified
value.
Specified value: 8000 to 8BC0
Note3:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
7
0
03
00
Set the data.
R-Y
2mm
B-Y
2mm
R-Y
B-Y
0.5mm
1mm
3mm
3mm
Fig. 6-1-13 (A).
Fig. 6-1-13 (B).