6-35
DCR-DVD100/DVD100E
8. White Balance Adjustment (PD-188 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
MOVIE (
)
Subject
Arbitrary
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
B
Adjustment Address
67, 68
Specified Value
The LCD screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC6001
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
B
67
7D
Set the data, and press PAUSE
button.
3
B
68
65
Set the data, and press PAUSE
button.
4
B
68
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
B
67
Change the data so that the LCD
screen is not colored.
6
B
67
Press PAUSE button.
7
B
68
Change the data so that the LCD
screen is not colored.
8
B
68
Press PAUSE button.
9
B
68
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.