Overview
16 (E)
This switcher performs self-diagnosis testing when
you turn the power on, reset the switcher, and at
regular intervals during operations. If the self-
diagnosis test detects an error, the status indicator
lights, and information about the error is output to the
terminal. The information about the error is also
output to the host computer of the ISR system if this
switcher is connected to the system. You can simply
determine the origination of the error through the 2-
digit error code shown on the ERROR NO. indicator
on the CPU-149 board. The errors possibly displayed
on the switcher and their respective countermeasures
are shown in the table below.
Refer to the maintenance manual for information
concerning the error codes displayed on the ERROR NO.
indicator and the appropriate countermeasures.
Error Indications and Countermeasures
Errors indicated by the status indicator and countermeasures
Indicator
Status
Meaning
Countermeasures
Green
Lit
Switcher operations are normal.
—
Green
Flashing
A synchronizing signal was not detected.
Supply a reference video signal.
Red
Lit
Both the CPU-149 and BKDS-V3290B have been
installed but there is a problem with one of the
boards.
Two power supply units are installed, but one of
the voltages is low.
Red
Flashing
One of the following errors was detected during
self-diagnosis:
•
Crosspoint hardware malfunction.
•
The temperature inside of the switcher is too high.
•
The fan stopped working.
•
An S-BUS link cable is cut.
The active board is indicated by the D5:ACT
indicator lit. The ACT indicator of the failed
board has gone off. Replace the failed board
with a new one and the corresponding ACT
indicator lights green again.
Replace the power supply unit on which the
+5 V or –5 V power indicator is not lit.
Find the source of the error using the terminal
display or error indication.