Chapter 7
Menu System
7-12
Chapter 7
Menu System
7-3 Extended Menu
Menu items in the 300s, relating to editing operations
Item number
Item name
Settings
301
VAR SPEED RANGE FOR
SYNCHRONIZATION
Select the playback speed range when carrying out playback in variable mode
from a remote control unit connected to the REMOTE-1 IN (9P) connector or
REMOTE-1 OUT (9P) connector.
–1~+2 : –1 to +2 times normal speed.
~+2.3 : –1.5 to +2.3 times normal speed.
wide : undefined
302
CAPSTAN RE-LOCKING
DIRECTION
In 525 mode
When the CAPSTAN LOCK switch on the subsidiary control panel is set to 4FD
select whether the capstan servo should lock by accelerating or decelerating.
DECEL : Lock by decelerating.
ACCEL: Lock by accelerating.
In 625 mode
When the CAPSTAN LOCK switch on the subsidiary control panel is set to 4FD
or 8FD select whether the capstan servo should lock by accelerating or
decelerating.
DECEL: Lock by decelerating.
ACCEL : Lock by accelerating.
305
SYNC GRADE
When editing in phase-synchronized mode with item 004 set to ON, select the
target phase synchronization accuracy.
ACCUR : ±0 frame accuracy.
ROUGH: ±1 frame accuracy.
307
AUTO-DELETION FOR
INCONSISTENT DATA
Select what happens when an erroneous edit point is set.
MANU : A warning is given by flashing the DELETE button on the lower control
panel.
The operator must manually delete the unnecessary edit points or correct the
erroneous edit point.
NEG&E: When inconsistent edit points are set, such as when an OUT point is
before an IN point, or an audio OUT point is before an audio IN point, or when
too many edit points are specified, the previously set edit point is deleted.
NEG: When inconsistent edit points are set, such as when an OUT point is before
an IN point, or an audio OUT point is before an audio IN point, the previously
set edit point is deleted. When too many edit points are specified, the DELETE
button on the control panel flashes to give a warning.
Note
Pressing the button corresponding to an edit point to be deleted and the DELETE
button simultaneously, deletes the edit point. If an erroneous edit point is set (the
DELETE button is flashing), editing is not executed.
308
SELECTION OF STD/
NON-STD FOR
COMPOSITE VIDEO IN
Select the STD or NON-STD mode in accordance with a composite video input.
AUTO : Detect automatically whether the input video luminance and chrominance
signals are interleaved or not. If they are interleaved, select the STD mode. If
they are not interleaved, select the NON-STD mode.
STD: The STD mode is always used (forced STD mode).
N-STD: Use this setting when color framing of the input video signal is unstable
(forced NON-STD mode).
306
DMC INITIAL SPEED
Select the initial speed automatically set when carrying out DMC editing.
MANUAL : The speed determined by the rotation of the search dial.
PLAY: Normal playback speed.
STILL: Stationary.
±0.03~±1, +2: Speed set in the range ±0.03 to +2 (select from +2, ±1, ±0.5, ±0.2,
±0.1, ±0.03).