DSC-W1/W12
6-27
3.
LED Check
Page 20
Address 04
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 20, address: 04, and set data: 02.
3) Select page: 8E, address: FE, and set data: 20.
4) Select page: 80, address: 12, and set data: 01.
5) Check that all LED are lit.
• SELF TIMER/AF ILLUMINATOR
• SELF TIMER/RECORRDING
• AE/AF LOCK
• FLASH CHARGE
• MS ACCESS
6) Select page: 80, address: 12, and set data: 00.
7) Select page: 20, address: 04, and set data: 00.
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
10) Click
[Disconnect]
on the SEUS screen.
11) Disconnect the USB cable.
12) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00 When data = 01 When data = 02
Shutter button
(XAE LOCK SW)
OFF
ON
ON
(CONTROL SWITCH BLOCK S001)
Shutter button
(XSHTR ON SW)
OFF
OFF
ON
(CONTROL SWITCH BLOCK S001)