5) Upon successful completion of the “AWB 3200K Check”, the
following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-32
6) Click the
[OK]
button, and the “7. AWB 5800K Standard Data
Input” and “8. AWB 5800K Check” will be executed.
7) Upon successful completion of the “AWB 5800K Check”, the
following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-33
8) Click the
[OK]
button, and the “9. AWB 3200K Check” and
“10. CCD Linearity Check” will be executed.
9) Upon successful completion of “10. CCD Linearity Check”,
the following message is displayed. Change the chart in ac-
cordance with the message.
Fig. 6-1-34
5.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Mechanical Shutter Adj.
5. Light Value Adj.
6. AWB 3200K Standard Data Input
7. AWB 5800K Standard Data Input
8. AWB 5800K Check
9. AWB 3200K Check
10. CCD Linearity Check
11. Color Reproduction Adj.
12. CCD White Defect Compensation Check
13. CCD Black Defect Compensation Check
14. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the
[CAMERA Adjustment 3 Start]
button.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-22 to
Fig. 6-1-24 (See page 6-16), set the subject and click the
[OK]
button.
Fig. 6-1-30
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-31
4) Click the
[OK]
button, and the items from “3. F No. Compen-
sation” to “6. AWB 3200K Standard Data Input” will be ex-
ecuted.