2-6-4. Self-Diagnosis Mode
Activate the self-diagnosis mode following the procedure
below.
n
The self-diagnosis mode of CNU-500 is completed when
the system is terminated normally or when an error occurs.
.
Turn on the power switch with the S4 and S5 switches
(on the AT-100 board panel) set to the DOWN and SET
positions, respectively.
a)
ROM/RAM Check
.
Release the switches when the monitor display shown in
Fig. 1 appears.
Fig. 1
Trouble 1
: Figure 1 is not displayed on the monitor
screen.
Remedy
: Confirm if IC45 and its peripheral block
or switches S3, S4, and S5 are not
defective.
Trouble 2
: The RAM check appears as an NG
display.
Remedy
: Confirm if IC9 to IC12 are not defective.
b) Switch Check
1.
Confirm that Fig. 1 is displayed on the monitor screen,
and set S2-1 to S2-8 sequentially to on (see in Fig. 2).
Next, set S2-8 to S2-1 sequentially to off and confirm
that the monitor display shown in Fig. 3 appears.
Fig. 2
Fig. 3
Trouble 3
: S2 appears as an NG display or appears
as neither an OK nor NG display.
Remedy
: Confirm if S2 or its peripheral block is
not defective.
2-6. Self-Diagnosis
S3
S4
S5
UP
DOWN
SET
CANCEL
MODE