2-4 (E)
CNU-500
RCP1
RCP2
RCP3
RCP4
RCP5
RCP6
VCS
AUX
REFERENCE
CCU1
CCU2
CCU3
CCU4
CCU5
CCU6
MSU
AC IN
RS232C
CCA-5-3 or CCA-5-10
AC
VBS or BB
Monitor
D-SUB 9-pin
short plug
75
Z
terminator
Signal genertor
Connect between the connectors to be checked using a CCA-5 cable
2-5. Notes on Service
2-5-1. Note on Replacement of Parts
1.
WARNING
Safety Related Components Warning
Components marked
!
are critical to safe operation.
Therefore, specified parts should be used in the case of
replacement.
2. Standardization of Parts
Some repair parts supplied by Sony differ from those
used for the unit. These are because of parts common-
ality and improvement.
Parts list has the present standardized repair parts.
3. Stock of Parts
Parts marked with “o” at SP(Supply Code) column of
the spare parts list may be not stocked. Therefore, the
delivery date will be delayed.
4. Units Representation
The following represented units are changed or
omitted in writing.
Units
Representation
Capacitance
µ
F
uF
Inductance
µ
H
uH
Resistance
Z
Abbreviation
Temperature
d
C
XXX
-DEG-C
5. Destination Representation
The part indicated “For J/UC/CE” in the spare parts
list is used in the unit written below.
For J
: The part is used in a unit for Japan.
For UC: The part is used in a unit for U.S.A. and
Canada.
For CE : The part is used in a unit for regions except
the above countries.
2-5-2. P ROM IC
Each PROM IC on the PC board has a suffix to its original
designation. This suffix may change according to improve-
ment of IC. Never use and IC having no suffix to its
original designation, because its memory has not been
programmed. Each PROM IC is mounted on the PC board
via socket.
2-6. Self-Diagnosis
CNU-500 has a self-diagnosis program. The state of this
unit can be diagnosed by using this self-diagnosis program.
2-6-1. Equipment Required
.
75
Ω
terminator
.
Coaxial cable
x
2
.
Monitor (A B/W monitor can be used.)
.
Signal generator (A VBS(
*
1) or BB(
*
2) signal can be
output.)
*
1 VBS : Video Burst and Sync Signal
*
2 BB
: Black Burst and Sycn Signal
.
D-SUB 9-pin connector plug (male) whose pins 2 and 3,
and pins 7 and 8 are shorted. (Referred to as a D-SUB 9-
pin short plug hereafter.)
.
CCA-5-3 cable or CCA-5-10 cable
x
1
2-6-2. Connection
2-6-3. Initial Setting
Set as described below before performing the self-diagnosis.
.
Remove the top panel. (Refer to “2-1, Cabinet Removal”.)
Panel switches of AT-100 board
.
S1102(OPERATION)
→
NORMAL
.
S3(MODE)
→
D
.
S6(SYNC)
→
ON
Inside switches on AT-100 board
.
S1100(H7)
→
S1100-2:ON
Except S1100-2:OFF
.
S2(H11)
→
all OFF
2-5. Notes on Service
2-6. Self-Diagnosis
Summary of Contents for CNU-500
Page 12: ......