1-4 (E)
CNU-500
POWER
CAMERA COMMAND NETWORK UNIT
408
65
123.8
212.7
263.5
4–M4
28
44
7
393
424
482
465
.
S6 (SYNC ON/OFF)
Used to specify whether a synchronizing signal is added to
the video signal output from the CHARACTER terminal.
Factory-setting : ON
.
S1100 (BAUD RATE SETTING)
SW No.
Setting Position
S1100-2
ON
OFF
OFF
OFF
OFF
OFF OFF
S1100-3
OFF
ON
OFF
OFF
OFF
OFF OFF
S1100-4
OFF
OFF
ON
OFF
OFF
OFF OFF
S1100-5
OFF
OFF
OFF
ON
OFF
OFF OFF
S1100-6
OFF
OFF
OFF
OFF
ON
OFF OFF
S1100-7
OFF
OFF
OFF
OFF
OFF
ON
OFF
S1100-8
OFF
OFF
OFF
OFF
OFF
OFF ON
BAUD RATE 19,200 9,600 4,800 2,400 1,200 600
300
Unit : bps
n
Be sure to set one of these switches to ON.Never set two or
more switches to ON or all switches to OFF.
Factory-setting : 19,200 bps.
S1100-1 : Not used
.
S1102 (OPERATION)
NORMAL:
Normal mode
EMERGENCY: When the CNU-500 or master setup unit
does not operate normally, set this switch
to EMERGENCY.The camera can be
controlled by the control panel.
Factory-setting : NORMAL
.
D4 (
+
5 V INDICATOR)
Lights when the
+
5 Vdc is supplied to the AT-100 board
correctly.
.
RV1 (CHARACTER PHASE)
Adjusts the horizontal phase with respect to the reference
signal of the video output from the CHARACTER
terminal.When the monitor is set to external sync signal,
the horizontal position of the CHARACTER can be
adjusted.
1-4. Installation
1-4-1. Installation Conditions
Operating temperature
:
+
5
d
C to
+
40
d
C
Storage temperature
:
_
20
d
C to
+
50
d
C
Humidity
: No condense
Power sources
: AC 100 V to 120 V(UC)
AC 110 V to 120 V/ AC 220 V
to 240 V(CE)
Power frequency
: 50/60 Hz
Power consumption
: 4 A (MAX):UC
2.5 A (MAX):CE
.
Install the unit in a location as dry and well-ventilated as
possible.
.
Do not install the unit in the following conditions.
High temperature room or near the heat source
Excessive dust or mechanical vibration
Intense magnetic and electric fields
A place subjected to direct sunlight or strong light