MVC-CD250/CD400
5-22
11. Auto White Balance 3200K Standard Data Input 3
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
84 to 87
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame set-
ting ”. (Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
06
6
6
01
0B
Press PAUSE button. (Note 3)
7
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 84 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
00
“Set data noted down at step
3, and press PAUSE button.”
4
Release the data setting per-
formed at step 1. (Refer to
page 5-14)
10. Auto White Balance 3200K Standard Data Input 2
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
7C to 7F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame set-
ting ”. (Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
04
6
6
01
0B
Press PAUSE button. (Note 3)
7
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 7C to 7F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
00
“Set data noted down at step
3, and press PAUSE button.”
4
Release the data setting per-
formed at step 1. (Refer to
page 5-14)
Summary of Contents for CD Mavica MVC-CD250
Page 33: ...Schematic diagram of the SY 76 board are not shown Pages from 4 15 to 4 40 are not shown ...
Page 43: ...Printed wiring board of the SY 76 board are not shown Pages from 4 57 to 4 60 are not shown ...
Page 51: ...Waveforms of the SY 76 board are not shown Pages 4 74 and 4 75 are not shown ...
Page 55: ...Mounted parts location of the SY 76 board are not shown Page 4 79 is not shown ...
Page 57: ...MVC CD250 CD400 5 1 COVER COVER SECTION 5 ADJUSTMENTS ...
Page 121: ...Electrical parts list of the SY 76 board are not shown Pages from 6 15 to 6 23 are not shown ...