3.
Flange Back Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment (1)
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 2B, 3E (MVC-CD250)
18 to 3E (MVC-CD400)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
6
01
13
Press PAUSE button.
3
6
01
15
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 2B and 3E (MVC-CD250)/18 to 3E
(MVC-CD400).
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-14)
3
Perform “Flange Back
Adjustment (2)”.
3-2. Flange Back Adjustment (2) (MVC-CD250 only)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subject with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 2B, 3E
Adjusting method:
Order Page Address Data
Procedure
1
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away. (Note 1)
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
3
6
01
13
Press PAUSE button.
4
Place ND filter on the lens so
that the optimum image is
obtain.
5
6
01
29
Press PAUSE button.
(Note 2)
6
6
02
Check the data changes to
“01”.
7
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 1:
Subject with clear contrast such as building, etc.
Nearby subjects less than 500 m away should not be in
the screen.
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 2B and 3E.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 5-14)
3
Perform “Flange Back
Check”.
Summary of Contents for CD Mavica MVC-CD250
Page 33: ...Schematic diagram of the SY 76 board are not shown Pages from 4 15 to 4 40 are not shown ...
Page 43: ...Printed wiring board of the SY 76 board are not shown Pages from 4 57 to 4 60 are not shown ...
Page 51: ...Waveforms of the SY 76 board are not shown Pages 4 74 and 4 75 are not shown ...
Page 55: ...Mounted parts location of the SY 76 board are not shown Page 4 79 is not shown ...
Page 57: ...MVC CD250 CD400 5 1 COVER COVER SECTION 5 ADJUSTMENTS ...
Page 121: ...Electrical parts list of the SY 76 board are not shown Pages from 6 15 to 6 23 are not shown ...