5-41
MVC-CD250/CD400
7.
V-COM Level Adjustment (PK-65/66 Board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
8
of CN714 on SY-76 board
(PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
87
Specified Value
A = 6.14
±
0.05 Vp-p
(MVC-CD400)
A = 5.42
±
0.05 Vp-p
(MVC-CD250)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
03
4
A
87
Change the data and set the
voltage (A) to the specified
value.
5
A
87
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
Fig. 5-1-21
A
2H
8.
V-COM Adjustment (PK-65/66 Board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
A
Adjustment Address
84
Specified Value
The brightness difference between
the section-A and section-B is
minimum
Note:
Perform “Contrast Adjustment” before this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
82
4
A
84
Change the data so that
brightness of the section A
and section B is equal.
5
A
84
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
Fig. 5-1-22
A
A
A
A
B
B
B
B
Summary of Contents for CD Mavica MVC-CD250
Page 33: ...Schematic diagram of the SY 76 board are not shown Pages from 4 15 to 4 40 are not shown ...
Page 43: ...Printed wiring board of the SY 76 board are not shown Pages from 4 57 to 4 60 are not shown ...
Page 51: ...Waveforms of the SY 76 board are not shown Pages 4 74 and 4 75 are not shown ...
Page 55: ...Mounted parts location of the SY 76 board are not shown Page 4 79 is not shown ...
Page 57: ...MVC CD250 CD400 5 1 COVER COVER SECTION 5 ADJUSTMENTS ...
Page 121: ...Electrical parts list of the SY 76 board are not shown Pages from 6 15 to 6 23 are not shown ...