TEMPERATURE SENSOR TEST
It can check the operation of temperature sensor.
(Refer to “LED position” on page 24 about position of LED)
Procedure:
1. Enter the servicing mode.
(Refer to “1. Setting method of servicing mode” on page 24)
2. Press the buttons on the remote commander that correspond to
each temperature sensor modes in order, and transmit the test
code to the main unit (Refer to the following table).
Note 1:
Press the each button in 150 ms or more interval, and perform the
all button operations in 7 seconds or less.
Mode
Buttons of remote commander
Temperature sensor test
for NAND
fl
ash memory
[AMP]
→
[DISPLAY]
→
[0/10]
→
[5]
→
[0/10]
→
[1]
→
[ ]
Temperature sensor test
for combination power
block
[AMP]
→
[DISPLAY]
→
[0/10]
→
[5]
→
[0/10]
→
[2]
→
[ ]
3. When entering each temperature sensor mode, a status indica-
tor LED light up, and it indicate the temperature that is de-
tected by temperature sensor.
Status indicator
LED
Temperature
“1” flashes
Less than 10°C
“1” lights up
10°C or more, and less than 20°C
“2” lights up
20°C or more, and less than 30°C
“3” lights up
30°C or more, and less than 40°C
“4” lights up
40°C or more, and less than 50°C
“5” lights up
50°C or more, and less than 60°C
“6” lights up
60°C or more, and less than 70°C
“7” lights up
70°C or more, and less than 80°C
“7” flashes
80°C or more
4. When releasing from the temperature sensor mode, press the
[AMP]
→
[DISPLAY]
→
[0/10]
→
[5]
→
[0/10]
→
[0/10]
→
[ ] buttons on the remote commander in order, and transmit
the test code to the main unit.
Note 2:
Press the each button in 150 ms or more interval, and perform the
all button operations in 7 seconds or less.
SETTING ALL RESET
It can delete the setting contents.
(Refer to “LED position” on page 24 about position of LED)
Procedure:
1. Enter the servicing mode.
(Refer to “1. Setting method of servicing mode” on page 24)
2. Press the buttons on the remote commander that correspond to
each setting all reset modes in order, and transmit the test code
to the main unit (Refer to the following table).
Note 1:
Press the each button in 150 ms or more interval, and perform the
all button operations in 7 seconds or less.
Mode
Buttons of remote commander
Setting all reset for
customer
[AMP]
→
[DISPLAY]
→
[0/10]
→
[8]
→
[0/10]
→
[1]
→
[ ]
Setting all reset for de-
signer (Complete clear)
[AMP]
→
[DISPLAY]
→
[0/10]
→
[8]
→
[0/10]
→
[2]
→
[ ]
Note 2:
It cannot delete the interlock information, history mode informa-
tion and serial number information with setting all reset mode for
customer.
3. When entering the setting all reset mode, all status indicator
LEDs
fl
ash (In addition, when entering the setting all reset
mode, all input indicator LEDs ([ ], [A], [B]) light up), and
when completing the reset, it becomes the standby status (Sta-
tus that servicing mode is released).