Service Adjustment
RM-GD020
RM-GD020, RM-CD013
KDL-32, 40, 46 CX523
KDL- 22, 32, 40, 46 CX520
In VPC service mode:
a. Select 000 DATA_COPY category by pressing key
2
or
5
on remote
commander.
b. Change data from
0
to
1
by pressing key
3
or
6
on remote commander.
c Wait until data is changed from
1
to
3
4-7. Restore WB / Gamma adj-data to B board.
4-8. Change the emitter output level (Applicable only for TD model).
1. Purpose to reduce the emitter LED output power strength.
2. Select VPC service mode and then press:
a. Select 005 TD category by pressing key
2
or
5
on remote commander.
b. Select 000 EMIT_STR item by pressing key
1
or
4
on remote commander.
c. Change data from
0
to
1
by pressing key
3
or
6
on remote commander.
c. Wait until data is changed from
1
to
3
.
d. When data is changed from
1
to
3
, restoring process is finished.
e. In case data is changed from
1
to
2
, keep default setting.
(No more process is needed.)
g
y p
g
y
0: Strong (Default)
1: Weak
d. Save by pressing
Mute
&
0
or
10
& Reboot.
VPC SERVICE
000 DATA_COPY
000 BU_TRANS 3
VPC SERVICE
000 DATA_COPY
000 BU_TRANS 1
DO NOT POWER OFF
b
a
VPC SERVICE
005 TD
000 EMIT_STR 1
End restore process menu
DATA TRANSFER SUCCESS
Restore process menu sample
DO NOT POWER OFF
DO NOT TOUCH ANY KEY NOW
a
b
b
c
Sub Service menu
sample
Remote Commander
d
Notes:
1. This restoration should be applied after USB-DL being assembled when
B Board is replaced.
2. This process only applicable for 120Hz / 240Hz models only.
Remote Commander