SECTION 3
TROUBLESHOOTING
RM-GD020, RM-CD013
KDL-32, 40, 46 CX523
RM-GD020
KDL- 22, 32, 40, 46 CX520
3-1. Power Problem
3-2. Standby Led Blinking
3-2-1. 2-times blinking (Main Power Error)
No Power
Turn on the Switch
Check
SW OFF
2-times blinking
Check STBY 3.3V
Replace the Harness
Turn on the Switch
** Power Saving Switch
NG
NG
SW ON
Check REG12V
at pins 2/3 of
CN6001 on
the B* Board
G* Board
Replace the Harness
Between G* Board and
B* Board
NO 12V
NG
at 10 pin of CN6001
on the B* Board
G* Board
Between G* Board and
B* Board
NG
OK
Symptom
improvement
the B* Board
B* Board
Harness
12V OK
Symptom
improvement
Harness
B* Board
**Power Saving Switch
:
Only for BAT-L model
Segment
Size
B* Board Type
G* Board Type
P-2
22
BAT-S
GD1
P-2
32
BAT-V G2A
P-2
40
BAT-V
G2B
P-2
46
BAT-V
G3
-10-