9
IP transmission connection example
Connection with devices that are SMPTE ST 2110 compliant is supported by installing an SKC-4001 ST 2110 Interface Kit in the
BPU4500A.
To use IP-related functions, connect with an HDCU3100/HDCU3500/HDCU5000, and use PTP synchronization on the CCU
device.
a)
a)
b)
b)
b)
b)
c)
d)
c)
c)
d)
c)
Audio mixer
a) Signal transfer over a maximum of 2 km is possible. However, the actual transfer distance may vary depending on the system configuration of the
cameras and the type of optical fiber cables used.
b) Connect to the LAN1 and LAN2 connectors of the SKC-4001 ST 2110 Interface Kit.
c) Connect to the LAN1 and LAN2 connectors of the HKCU-SFP30 ST 2110 Interface Kit.
d) Connect to the LAN-COM connector of the HDCU3100.
e) Install the SKC-4001 ST 2110 Interface Kit.
f) Install the HKCU-SFP30 ST 2110 Interface Kit.
Multi viewer
Video server
PTP master × 2
IP intercom
IP tally system
IP switch
10G/1G
IP switch
100M/1G
IP switch
× 2
10G/25G
Optical fiber cable
LAN cable
MSU-1000 series
Master Setup Unit
HDC4300 Color Camera
BPU4500A
e)
HDCU3100
Camera Control Unit
f)
HDC4300 Color Camera
BPU4500A
e)
HDCU3100
Camera Control Unit
f)
IP Live System
Manager × 2