2-2 (E)
BKP-5090
4. Loading data from the EEPROM
(1) Set the switches S1-1 to S1-4 on the AT-126 board as follows:
S1-1
S1-2
S1-3
S1-4
OFF
ON
OFF
ON
(2) [BVP-550/550P]
Power on the unit while pressing the CANCEL button.
[BVP-500/500P]
Power on the unit while pushing down the MENU SELECT button to CANCEL.
(3) Until the message “Paint clear” is displayed on the viewfinder screen;
[BVP-550/550P]
Continue to press the CANCEL button.
[BVP-500/500P]
Push down the MENU SELECT button to CANCEL several times.
(4) Set the switches S1-1 to S1-4 on the AT-126 board as follows:
S1-1
S1-2
S1-3
S1-4
ON
OFF
ON
OFF
2-1-2. Auto Setup
1. Executing the black auto setup
[BVP-500/500P/550/550P: By using the MSU-700 (for system use)]
Press and light the BLACK button in the AUTO SETUP block of MSU.
[BVP-550/550P: for standalone use]
Set the AUTO W/B BAL switch on the camera front panel to BLK.
2. Executing the level auto setup
[BVP-500/500P/550/550P: By using the setup menu]
MENU: Operation
PAGE: Auto Setup (?8)
ITEM: Auto Level
(Press the MENU SELECT switch to ENTER to execute for the BVP-500/500P, or press the MENU SEL
switch to execute for the BVP-550/550P.)
[BVP-500/500P/550/550P: By using the MSU-700 (for system use)]
(1) Press and light the LEVEL button in the AUTO SETUP block of MSU.
(2) Press and light the START/BREAK button in the AUTO SETUP block of MSU.
2-1. Preparation
2-1-1. Clearing Files
2-1-2. Auto Setup