3-1(E)
SECTION 3
CIRCUIT ADJUSTMENTS
The BKM-48X is an optional board for the HDM series, BVM
series, and therefore will not operate on its own. To adjust
and measure it, BKM-48X must be mounted with the HDM
series monitor, BVM series monitor. The HDM series moni-
tor, BVM series monitor used in these adjustments should
satisfy the respective specifications.
3-1. PREPARATIONS FOR BHA BOARD
ADJUSTMENTS
3-1-1. When mounting to BVM
Set as follows in the INPUT CONFIGURATION menu of
the SETUP menu.
• 01 CH
FORMAT ............... RGB
SLOT NO. .............. n (Set to the slot number with the
BHA inserted)
INPUT NO. ............ 123
SYNC MODE ........ INT
• 02 CH
FORMAT ............... YUV
Same as 01 CH for others
• 03 CH
FORMAT ............... NTSC 0
SLOT NO. .............. n (Set to the slot number with the
BHA inserted)
INPUT NO. ............ 1
YC SEP .................. COMP
SYNC MODE ........ INT
APERTURE ........... OFF
FILTER .................. OFF
CONTROL ............. PRESET
H PHASE ............... 000
• 04 CH
FORMAT ............... YC NTSC 0
Same as 03 CH for others
• 05 CH
FORMAT ............... RGB
INPUT NO ............. 456
Same as 01 CH for others
* Mount together with the BKM-24N or BKM-27T.
3-1-2. When mounting to HDM
Set as follows in the INPUT CONFIGURATION menu of
the SETUP menu.
• 01 CH
FORMAT ............... GBR
SLOT NO. .............. n (Set to the slot number with the
BHA inserted)
INPUT NO. ............ 123
SYNC MODE ........ INT
• 02 CH
FORMAT ............... YP
B
P
R
Same as 01 CH for others
• 03 CH
FORMAT ............... GBR
INPUT NO ............. 456
Same as 01 CH for others