12
Powering down
Shutting the storage unit down
▶
Shut off the grid source to the storage unit e.g.
main AC breaker in main service entrance, AC
service disconnect, etc.
▶
Determine if your storage unit has a front panel
display screen.
With front panel display screen.
▶
Press the icon with the 6 dots in the upper right
hand corner of the screen.
▶
Press "Settings".
▶
Press "Shutdown".
The storage unit will take approximately 60
seconds to completely shutdown.
Without front panel display screen
▶
Open cabinet.
▶
Turn off power switch (F1).
Turn off battery modules
▶
Press the power button on battery #0 for 3
seconds.
▶
Wait for all battery power LEDs to go off.
▶
Ensure both the "Power" and "Status" LEDs are
off on each battery module.
Emergency switch-off
In case of an emergency, the storage system
can be switched off by the main circuit breaker F1
or the external emergency switch (if installed).
Fig. 10 F1 circuit breaker
▶
In case of an emergency, switch off the main
circuit breaker F1 in the interior of the main
cabinet or the external emergency switch (if
installed).
▶
Only switch off the main circuit breaker F1 if it
can be reached without danger.
▶
If possible, shut off battery modules by
depressing the "Power" button for 3 seconds,
the batteries may take several seconds the
power down.
Recycling and certificates
This battery system complies with RoHS and
contains none of the following substances:
lead, cadmium, mercury, hexavalent
chromium, polybrominated biphenyl (PBB) and
polybrominated diphenyl ether (PBDE).
▶
To dispose of the storage system:
‒
Do not dispose of the storage system and its
battery modules in your household refuse!
‒
Contact service or the company that
installed your storage system and
commission them to disassemble and dispose
of the storage system.
Your battery modules will be recycled and
disposed of in an environmentally friendly manner.
S1
F1