![Sonifex NICA X Reference Manual Download Page 58](http://html1.mh-extra.com/html/sonifex/nica-x/nica-x_reference-manual_1321173058.webp)
NICA X Reference Manual
50
A
PPENDIX
A C
ONNECTION
D
ETAILS
A.1 X21 Ports
All cables must be under 3 metres in length. All cables terminated in D-type connectors must use screen cable with
screened connector hoods. The screen should be connected to the D shells. The X21 port connectors on the rear of
the units are 15 way D-type female connectors. A connection is normally made pin to pin.
Pin
Signal
Type at Nica X
Description
1
-
-
Not connected
2
TA
Output
Transmit A
3
CA
Output
Control A
4
RA
Input
Receive A
5
IA
Input
Indicate A
6
SA
Input
Bit Timing A
7
-
-
Not Connected
8
GND
-
Ground
9
TB
Output
Transmit B
10
CB
Output
Control B
11
RB
Input
Receive B
12
IB
Input
Indicate B
13
SB
Input
Bit Timing B
14
-
-
Not Connected
15
-
-
Not Connected
A.2 Auxiliary RS232 Data Port
All Cables must be under 3 metres in length. All cables terminated in D-type connectors must use screen cable
with screened connector hoods. The screen should be connected to the D shells. The auxiliary RS232 data port on
the rear of the unit is a 9 way D-type male connector. The minimum connections required are RX, TX and GND.
This provides access for two auxiliary ports.
Pin
Signal
Type
Description
Example PC Connection
1
AUX2 TXD
Input
Transmit Data
2
AUX1 RXD
Output
Receive Data
2
3
AUX1 TXD
Input
Transmit Data
3
4
-
-
-
5
SG
-
Signal Ground
5
6
AUX2 RXD
Output
Receive Data
7
APT CTS
Output
Clear to Send
8
APT RTS
Input
Request to Send
9
-
-
-
The APT CTS and APT RTS line are for use with the APT codec version only.
In a Dual Codec system the AUX1 is for the CH1 Codec Mode and AUX2 is for the CH2 codec Mode.
A.3 Remote Control Port
All cables must be under 3 metres in length. All cables terminated in D-type connectors must use screen cable with
screened connector hoods. The screen should be connected to the D shells. The Remote Control Port has an RS232
and RS485 interface. It is a 9 way D-type female connector. The minimum connections required are RX, TX and
GND.
Pin
Signal
Type
Description
Example PC Connection
1
-
-
2
RS232 RXD
Output
Receive Data
2
3
RS232 TXD
Input
Transmit Data
3
4
RS485 A
I/O
Data Bus A
5
SG
-
Signal Ground
5
6
-
-
7
RS485 PT
+ve terminator
8
RS485 B
I/O
Data Bus B
9
RS485 NT
- ve terminator
Summary of Contents for NICA X
Page 1: ...NICA X Codec System Reference Manual ...
Page 6: ...NICA X Reference Manual ...
Page 25: ...NICA X Reference Manual 17 ...
Page 26: ...NICA X Reference Manual 18 ...
Page 27: ...NICA X Reference Manual 19 ...
Page 43: ...NICA X Reference Manual 35 CHAPTER 7 APPLICATION DIAGRAMS ...
Page 44: ...NICA X Reference Manual 36 ...
Page 45: ...NICA X Reference Manual 37 ...
Page 46: ...NICA X Reference Manual 38 ...
Page 47: ...NICA X Reference Manual 39 ...