![Sonifex NICA X Reference Manual Download Page 56](http://html1.mh-extra.com/html/sonifex/nica-x/nica-x_reference-manual_1321173056.webp)
NICA X Reference Manual
48
Select Relay Output Actions (EXO)
DESCRIPTION:
Configure the actions that will activate the relay outputs.
SYNTAX:
<unit id>:EXO <relay no>,<user>
RESPONSE:
<respcode>,<relay number>,<user>
PARAMETERS:
<relay no> = a valid relay number ( 1 to 8 ).
<user> = 0 - relay under command control, 1 - default action for this relay.
EXAMPLE:
(PC)
0:EXO1,1
↵
(NX)
00,1,1
↵
Select Remote Control Inband Enable (REM)
DESCRIPTION:
Enable inband channel for remote control commands.
SYNTAX:
<unit id>:REM <enable>
RESPONSE:
<respcode>
PARAMETERS:
<enable> = 0 - disabled, 1 - enabled , 2 - debug (connects aux to ISDN TA management port)
EXAMPLE:
(PC)
0:REM 1
↵
(NX)
00
↵
Set Auxiliary Data Rate (AUX)
DESCRIPTION:
Configure the auxiliary channels data rate.
SYNTAX:
<unit id>:AUX <data rate 1>,<data rate 2
RESPONSE:
<respcode>,<data rate 1>,<data rate 2>
PARAMETERS
:
<data rate 1> = one of :-
<data rate 2> = one of :-
0: off
4: 9600baud
3: 4800baud
2: 2400baud
1: 1200baud
EXAMPLE:
(PC)
0:AUX
↵
(NX)
00,4,1
↵
Set Codec Mode (MOD)
DESCRIPTION:
Set the codec’s mode of operation.
SYNTAX:
<unit id>:MOD <main mode>, <secondary mode>
RESPONSE:
<respcode>, <main mode>, <secondary mode>
PARAMETERS:
<main mode> = a valid mode number.
<secondary mode> = a valid mode number.
EXAMPLE:
(PC)
0:MOD0,15
↵
(NX)
02
↵
i.e. Set the secondary codec mode to mode 15; the NICA X rejects the command due to an error with parameter 2.
Signal Private User (SPU)
DESCRIPTION:
MPEG modes have a "Private User" bit available for application dependent in-band signalling. This
command can set or clear this bit. If the far end is another NICA X, the received bit can be read
by a RIP command, or the unit can be programmed to execute a stored command on a change.
This command is always accepted, even while the codec is not connected in an MPEG mode.
Whenever it is connected in an MPEG mode, the last stored value is transmitted.
SYNTAX:
<unit id>:SPU <chno>, <on>
RESPONSE:
<respcode>
PARAMETERS:
<chno> - The channel number, 1 or 2.
<on> - Value to set the Private User bit, 0 or 1.
EXAMPLE:
(PC)
0:SPU2,1
↵
(NX)
00
↵
Sound System Buzzer (BUZ)
DESCRIPTION:
Sound the internal buzzer.
SYNTAX:
<unit id>:BUZ<on time>,<off time>,<count>
RESPONSE:
<respcode>
PARAMETERS:
<on time> - time to sound buzzer in 1/4 seconds
<off time> - time to remain silent before repeat.
<count> - number of times to repeat the buzz.
Summary of Contents for NICA X
Page 1: ...NICA X Codec System Reference Manual ...
Page 6: ...NICA X Reference Manual ...
Page 25: ...NICA X Reference Manual 17 ...
Page 26: ...NICA X Reference Manual 18 ...
Page 27: ...NICA X Reference Manual 19 ...
Page 43: ...NICA X Reference Manual 35 CHAPTER 7 APPLICATION DIAGRAMS ...
Page 44: ...NICA X Reference Manual 36 ...
Page 45: ...NICA X Reference Manual 37 ...
Page 46: ...NICA X Reference Manual 38 ...
Page 47: ...NICA X Reference Manual 39 ...