35
Embedded Web Server 8
Normal Layout
Meter Characteristics
Scale Range Without
Phase Meter
Scale Range with Phase
Meter
0dBFS
Reference
Start of Amber
Section
Start of
Red Section
Dual PPM + Standard VU
-8 to +12dBu
-2 to +12dBu
+18dBu
0dBu
+8dBu
EBU PPM
-9 to +12 dBu
-7 to +12 dBu
+18dBu
0dBu
+8dBu
BBC PPM
-8 to +12 dBu
-5 to +12 dBu
+18dBu
0dBu
+8dBu
Nordic PPM
-30 to +12 dBu
-26 to +12 dBu
+18dBu
0dBu
+6dBu
AES Digital PPM
-42 to 0 dBFS
-38 to 0 dBFS
+18dBu
-18dBFS
0dBFS
DIN PPM
-23 to +11 dBu
-19 to +11 dBu
+18dBu
-3dBu
+4dBu
German PPM
-32 to +15 dBu
-26 to +15 dBu
+15dBu
-32dBu
+7dBu
SMPTE RP.0155
-42 to 0 dBFS
-38 to 0 dBFS
+18dBu
-20dBFS
0dBFS
Standard VU
-18 to +3 VU
-16 to +3 VU
+18dBu
-4VU
0VU
Extended VU
-16 to +15 VU
-12 to +15 VU
+18dBu
-4VU
0VU
Table 8-1: Normal Layout.
Detailed View
Meter Characteristics
Scale Range Without
Phase Meter
Scale Range with Phase
Meter
0dBFS
Reference
Start of
Amber Section
Start of
Red Section
Dual PPM + Standard VU
-17 to +12 dBu
-14 to +12 dBu
+18dBu
0dBu
+8dBu
EBU PPM
-17 to +12 dBu
-14 to +12 dBu
+18dBu
0dBu
+8dBu
BBC PPM
-16 to +12 dBu
-13 to +12 dBu
+18dBu
0dBu
+8dBu
Nordic PPM
-47 to +12 dBu
-41 to +12 dBu
+18dBu
0dBu
+6dBu
AES Digital PPM
-59 to 0 dBFS
-53 to 0 dBFS
+18dBu
-18dBFS
0dBFS
DIN PPM
-48 to +11 dBu
-42 to +11 dBu
+18dBu
-3dBu
+4dBu
German PPM
-64 to +15 dBu
-58 to +15 dBu
+15dBu
-54dBu
+7dBu
SMPTE RP.0155
-59 to 0 dBFS
-53 to 0 dBFS
+18dBu
-20dBFS
0dBFS
Standard VU
-26 to +3 VU
-23 to +3 VU
+18dBu
-4VU
0VU
Extended VU
-68 to +15 VU
-56 to +15 VU
+18dBu
-4VU
0VU
Table 8-2: Detailed View.