Sonance DSP 2-750 Instruction Manual Download Page 14

12

SONAMP DSP 2-150 MULTI-CHANNEL POWER AMPLIFIER INSTRUCTION MANUAL

ACCESSING 

In order to access the             software on a DSP amplifier the 
amplifier needs to be on and connected to a router. The router will 
provide the DSP amplifier with an IP address automatically.

Using a Windows computer running Windows 7 or 8 the amplifier 
can be found in your network connections. The DSP amplifiers 
feature UPnP (Universal Plug and Play) allowing them to be displayed 
as easily accessible network devices. When multiple amplifiers are 
connected to the same network they will appear individually.

To find the IP address on a Mac computer or iOS device you will need 
to use an IP address scanner software or app. The manufacturer 
name should be displayed as Sonance on the DSP amplifier in your 
IP scanning software.      

Once you have the IP address you can use any internet browser to 
access the                            software. Type the DSP amplifier’s IP address into 
the URL bar. When the page loads you should be presented with the      
               General Settings tab.

IP SETUP 

DHCP On/Off

DHCP ON / OFF is the first option in IP SETUP. All Sonance DSP series 
amplifiers ship with DHCP (Dynamic Host Connection Protocol) ON. 
In most installations DHCP should be left ON. If you are controlling 
the DSP series amplifier using IP then we suggest you turn DHCP 
OFF and use a static IP address. 

IP Address

The second setting in the IP SETUP section is the IP address. 

When DHCP is ON the current IP address will be displayed. To 
change the IP address DHCP must be set to OFF.

When DHCP is turned off the IP address that the router assigned to 
the amplifier will still be applied. This IP address is a good place to 
start since it is not being used by another network device. If you wish 
to change the IP address you should perform a scan of the network 
and only assign an unused IP address within the range of your 
router. As a general rule only change the last three digits of the IP 
address in the amplifier settings and only assign numbers between 
1 and 254. Following this suggestion will minimize the chance of 
making the amplifier inaccessible.  

It is critical to type in the correct IP address. If the wrong IP address 
is entered, the amplifier could become inaccessible. Make changes 
to the IP settings only if you fully understand network setup. 

IP Subnet Mask

The third setting in the IP SETUP section is the IP Subnet Mask. This 
is an advanced network setup function. Under most circumstances 
this field should not need to be edited. Making changes in this field 
should only be done by experienced network administrators.

Color Coded Interface

Toggle/Pull-down Menu  

Free Type Field   

Single Action Menu

Summary of Contents for DSP 2-750

Page 1: ...SONAMP MULTI CHANNEL POWER AMPLIFIER WITH DSP 2 150 INSTRUCTION MANUAL...

Page 2: ...ction Box Contents 3 Front Panel Rear Panel 4 Amplifier Power Requirement Chart 6 Connections and Volume Level Controls 7 Protection Circuitry and LEDs 8 Network Connection Instructions 9 Quick Setup...

Page 3: ...n the amplifier use canned air or wipe the amplifier with a soft cloth Do not use solvents as they may damage the amplifier 12 Non use periods Unplug the amplifier s power cord from the outlet when th...

Page 4: ...e si l appareil a t endommag pour quelque raison que ce soit et par exemple si le c ble d alimentation secteur ou sa prise sont endommag s si du liquide a p n tr l int rieur de l appareil ou un objet...

Page 5: ...any object on or against the amplifier Never operate the amplifier on a carpeted surface as this will compromise ventilation When the amplifier is installed in any cabinet the front or back must be o...

Page 6: ...POWER AMPLIFIER FRONT PANEL DSP 2 150 Front Panel 1 Illuminated Power Button 2 Power Active Protection Indicator LED 3 Recessed Volume Level Control DSP 2 150 Rear Panel 4 L R Line In Loop Outputs 5 S...

Page 7: ...r will depend on the output capability of your source component Speaker Connections The removable block connectors used on the Sonamp amplifiers will accept up to 12 gauge wire Follow the connection l...

Page 8: ...dio inputs to the DSP 2 150 amplifier see Figure 8 Primary Line Inputs 1 L 1 R Use these inputs for primary audio source Secondary Line Inputs 2 L 2 R Use these inputs for a secondary audio source pag...

Page 9: ...the left and right inputs there are also loop outputs for each channel The loop outputs allow multiple amplifiers to share common audio sources The loop outputs on the amplifiers are not buffered The...

Page 10: ...AN EXTENDED PERIOD OF TIME CAN DAMAGE THE AMPLIFIER Amplifier Power Supply Protection DSP 2 150 The amplifier also has protection for the power supply If the power supply heat sink temperature exceed...

Page 11: ...an IP address by the router 5 Use an IP Scanner to determine the IP Addresses of the Sonance DSP amps on the network We recommend Fing app for IOS https itunes apple com us app fing network scanner id...

Page 12: ...n on the amplifier 4 The amplifier will be issued an IP address by the router 5 Click on Start and select Computer This PC Windows 7 or 8 or higher a For Windows XP download Advanced IP for Windows ht...

Page 13: ...ume the same as the Output Level a Its important to set the Turn On Volume the same in case the amplifier power is shut off accidentally The basic setup is complete Apply DSP Preset Follow the Network...

Page 14: ...controlling the DSP series amplifier using IP then we suggest you turn DHCP OFF and use a static IP address IP Address The second setting in the IP SETUP section is the IP address When DHCP is ON the...

Page 15: ...ge from 3 30 volts is applied to the rear panel connector the amplifier will turn on and off IP When the amplifier is connected to a network and an IP command is sent to the amplifier it will turn the...

Page 16: ...ut Setup Output Name This is a user entered field with a maximum of 16 characters Use these fields to describe the location of the speakers Stereo Mono Allows each channel to be set for Stereo or Mono...

Page 17: ...volume ranges between 70 to 12 The default volume level controls are set at 0 Output Volume This is the main volume level control for each channel When channels are placed in the same Output Group th...

Page 18: ...s page Test Signal The software includes a built in pink noise generator The pink noise signal can be used in conjunction with a real time analyzer to measure speakers Test Signal Select You have the...

Page 19: ...pull down menu You can save the new preset in any of the open preset locations or you can overwrite an existing preset you do not need 3 Press the green IMPORT button 4 You will be directed to my com...

Page 20: ...dual dip in the lower midrange EQ9 shows ON at 3000Hz the Q is set to 10 with a 6dB gain creating a sharp dip in the midrange EQ10 shows ON at 10000Hz the Q is set to 1 with a 4dB gain creating a very...

Page 21: ...ith a 5dB gain creating a gradual tilt in the high frequencies HP Xover set to ON at 90Hz with a 24dB Filter Type This is an example only to explain the settings Your settings will differ Tilt Control...

Page 22: ...receivers and processor contain an automatic calibration and equalization system If yours does contain one follow the manufacturer s instructions on how to complete the process The highest performance...

Page 23: ...er 74 Watts all channels driven idle 31 Watts IP or IR standby 1 5 Watts standby 0 48 Watts Power Consumption 220V AC 8 ohms sinewave full power 359 Watts all channels driven 4 ohms sinewave full powe...

Page 24: ...IDENTAL ECONOMIC PROPERTY BODILY INJURY OR PERSONAL INJURY DAMAGES ARISING FROM THE PRODUCT ANY BREACH OF THIS WARRANTY OR OTHERWISE This warranty statement gives you specific legal rights and you may...

Reviews: