Sonance DSP 2-750 Instruction Manual Download Page 13

11

SONAMP DSP 2-150 MULTI-CHANNEL POWER AMPLIFIER INSTRUCTION MANUAL

Quick Setup

Follow  the              Network  Setup  instructions  to  access  the                  
                software.

General Settings Tab - Auto On

Select the AUTO ON method you would like to use.

NOTE: IF EITHER AUDIO OR VOLTAGE TRIGGERS ARE SELECTED, THE 
AMPLIFIER HAS A 12 SECOND CYCLE TIME FROM STANDBY TO PLAY 
AN AUDIO SIGNAL. THIS IS NORMAL AND REQUIRED TO COMPLY 
WITH THE EU < .5 WATT ERP DIRECTIVE. (EC/1275/2008). SELECT 
OFF TO BYPASS THIS FEATURE. SEE POWER CONSUMPTION TABLE 
FOR IDLE POWER USE (SEE PAGE 6, FIGURE 7). AUDIO AUTO ON 
IS THE ONLY MODE THAT ALLOWS THE AMPLIFIER TO DRAW 0.5 
WATTS AT STANDBY. 

NOTE: WHEN VOLTAGE, POWER BUTTON, IP OR IR IS SELECTED THE 
AMPLIFIERS POWER SAVING FEATURE WILL BE DISABLED.

In/Out Settings Tab - Output Setup 

Select the preloaded DSP preset that matches your 

 

Sonance speaker.

If the DSP preset for your Sonance speaker is not included in the 
amplifier, follow the instructions to the right to add DSP presets.

In/Out Settings Tab - Output Source 

The amplifier default is Input 1 to Output 1, Input 2 to Output  
2, etc. If your application is different, assign the correct input to  
each of the output channels you will be using. Any left Input can  
be assigned to any left Output. Any right Input can be assigned to  
any right Output.

In/Out Settings Tab - Output Volume

 

If you are using a control system to adjust the volume you can skip 
these steps. 

1.  Set the Output Volume for each channel.

2.  Set the Turn On Volume the same as the Output Level.
   

a. Its important to set the Turn On Volume the same in  

   

  case the amplifier power is shut off accidentally. 

The basic setup is complete!

Apply DSP Preset

Follow the        Network Setup instructions to access the 
               software if not completed already.

Each Sonance DSP amplifier has 50 slots with pre-configured DSP 
curves for Sonance speaker models pre-loaded. If the speaker 
model in your application is not on the pre-loaded list, hundreds 
of DSP files are available for download from the Sonance website.

Sonance Website

Download the preset for your specific Sonance speaker model 

 

at www.sonance.com/electronics/amplifiers/dsp

DSP presets are also available for download on individual speaker 
web pages.

Save the new preset in a location on your computer you will be able 
to find later.

EQ Settings - Tab

1.  In the blue box labeled SELECT EQ PRESET choose which preset  
  number you would like to use to store your new EQ Preset.  
  You can overwrite presets you will not use.

2.  Press the Green Import Single EQ Preset button.

3.  Select the file you downloaded from the Sonance website.

4. The file will now be loaded into the preset location you 
  have selected.

5.  If necessary edit the name of the preset.

In/Out Settings Tab - Output Setup

 

Select the new EQ Preset from the drop down list and apply it to the 
appropriate amplifier channels.

Your new EQ preset has been applied! 

You can now apply the EQ preset to the channel on the EQ Settings 
page at the top.

Quick Setup Page

If you will be using the Sonance DSP amplifier with a control system and only want to make basic changes to the                software these 
instructions will guide you through the process.

Summary of Contents for DSP 2-750

Page 1: ...SONAMP MULTI CHANNEL POWER AMPLIFIER WITH DSP 2 150 INSTRUCTION MANUAL...

Page 2: ...ction Box Contents 3 Front Panel Rear Panel 4 Amplifier Power Requirement Chart 6 Connections and Volume Level Controls 7 Protection Circuitry and LEDs 8 Network Connection Instructions 9 Quick Setup...

Page 3: ...n the amplifier use canned air or wipe the amplifier with a soft cloth Do not use solvents as they may damage the amplifier 12 Non use periods Unplug the amplifier s power cord from the outlet when th...

Page 4: ...e si l appareil a t endommag pour quelque raison que ce soit et par exemple si le c ble d alimentation secteur ou sa prise sont endommag s si du liquide a p n tr l int rieur de l appareil ou un objet...

Page 5: ...any object on or against the amplifier Never operate the amplifier on a carpeted surface as this will compromise ventilation When the amplifier is installed in any cabinet the front or back must be o...

Page 6: ...POWER AMPLIFIER FRONT PANEL DSP 2 150 Front Panel 1 Illuminated Power Button 2 Power Active Protection Indicator LED 3 Recessed Volume Level Control DSP 2 150 Rear Panel 4 L R Line In Loop Outputs 5 S...

Page 7: ...r will depend on the output capability of your source component Speaker Connections The removable block connectors used on the Sonamp amplifiers will accept up to 12 gauge wire Follow the connection l...

Page 8: ...dio inputs to the DSP 2 150 amplifier see Figure 8 Primary Line Inputs 1 L 1 R Use these inputs for primary audio source Secondary Line Inputs 2 L 2 R Use these inputs for a secondary audio source pag...

Page 9: ...the left and right inputs there are also loop outputs for each channel The loop outputs allow multiple amplifiers to share common audio sources The loop outputs on the amplifiers are not buffered The...

Page 10: ...AN EXTENDED PERIOD OF TIME CAN DAMAGE THE AMPLIFIER Amplifier Power Supply Protection DSP 2 150 The amplifier also has protection for the power supply If the power supply heat sink temperature exceed...

Page 11: ...an IP address by the router 5 Use an IP Scanner to determine the IP Addresses of the Sonance DSP amps on the network We recommend Fing app for IOS https itunes apple com us app fing network scanner id...

Page 12: ...n on the amplifier 4 The amplifier will be issued an IP address by the router 5 Click on Start and select Computer This PC Windows 7 or 8 or higher a For Windows XP download Advanced IP for Windows ht...

Page 13: ...ume the same as the Output Level a Its important to set the Turn On Volume the same in case the amplifier power is shut off accidentally The basic setup is complete Apply DSP Preset Follow the Network...

Page 14: ...controlling the DSP series amplifier using IP then we suggest you turn DHCP OFF and use a static IP address IP Address The second setting in the IP SETUP section is the IP address When DHCP is ON the...

Page 15: ...ge from 3 30 volts is applied to the rear panel connector the amplifier will turn on and off IP When the amplifier is connected to a network and an IP command is sent to the amplifier it will turn the...

Page 16: ...ut Setup Output Name This is a user entered field with a maximum of 16 characters Use these fields to describe the location of the speakers Stereo Mono Allows each channel to be set for Stereo or Mono...

Page 17: ...volume ranges between 70 to 12 The default volume level controls are set at 0 Output Volume This is the main volume level control for each channel When channels are placed in the same Output Group th...

Page 18: ...s page Test Signal The software includes a built in pink noise generator The pink noise signal can be used in conjunction with a real time analyzer to measure speakers Test Signal Select You have the...

Page 19: ...pull down menu You can save the new preset in any of the open preset locations or you can overwrite an existing preset you do not need 3 Press the green IMPORT button 4 You will be directed to my com...

Page 20: ...dual dip in the lower midrange EQ9 shows ON at 3000Hz the Q is set to 10 with a 6dB gain creating a sharp dip in the midrange EQ10 shows ON at 10000Hz the Q is set to 1 with a 4dB gain creating a very...

Page 21: ...ith a 5dB gain creating a gradual tilt in the high frequencies HP Xover set to ON at 90Hz with a 24dB Filter Type This is an example only to explain the settings Your settings will differ Tilt Control...

Page 22: ...receivers and processor contain an automatic calibration and equalization system If yours does contain one follow the manufacturer s instructions on how to complete the process The highest performance...

Page 23: ...er 74 Watts all channels driven idle 31 Watts IP or IR standby 1 5 Watts standby 0 48 Watts Power Consumption 220V AC 8 ohms sinewave full power 359 Watts all channels driven 4 ohms sinewave full powe...

Page 24: ...IDENTAL ECONOMIC PROPERTY BODILY INJURY OR PERSONAL INJURY DAMAGES ARISING FROM THE PRODUCT ANY BREACH OF THIS WARRANTY OR OTHERWISE This warranty statement gives you specific legal rights and you may...