Before using the product for the first time, please read the
instructions for use below and retain them for later reference.
The original instructions were written in the Hungarian language.
This weather-resistant LED floodlight is perfectly suited for illuminating
buildings or yards.
With the help of the adjustable base it can be mounted on
horizontal as well as on vertical surfaces.
INSTALLATION
Warning! Installation should only be performed by a specialist, in compliance with the safety
and contact protection regulations in force!
1.
Warning! Power off the electrical power network before mounting and connecting the
luminaire!
2. The luminaire is not suitable for looping-in installation!
3. The luminaire may only be connected to built power network!
4. Before fixing it, please confirm that all parts required are present!
Connect the protruding free wire ends of the luminaire in a waterproof junction box to
the network. ATTENTION! This ensures the IP65 protection!
Use H05RN-F, 3 x min. 1,0 mm2 type wire!
5. Wires have to be connected as follows.
6
.
With the help of screws and dowels, mount the luminaire on a wall with adequate
bearing capacity, at least 1,8 m from the floor level, but max. 5 m high.
7
.
Power on the luminaire only after this process.
MOTION SENSOR
The lamp is switched on by the built-in motion sensor and operates only for the preset time.
If continuous movement is detected in the observed space, the delay time of the switch-off
starts from the end of the movement.
This time interval can be set from 10 seconds to 4
minutes with the TIME knob.
Another feature is the ability to switch on depending on the
ambient brightness. The LUX button is used to adjust the brightness, below which the
device is switched on (10-20,000 LUX). In this way, the lamp will not work unnecessarily.
The sensing distance can be adjusted using the SENS button, approx. between 4 and 12
meters.
(
figure 1.
)
The illustration showing the detection range may help with selecting the mounting location.
(
figure 2.
)
CLEANING AND MAINTENANCE
In order to ensure optimum functioning of the luminaire, the unit may require cleaning at
least once a month, depending on the manner of use and degree of contamination.
1.
Power off the luminaire before cleaning!
2.
Allow the luminaire to cool (for at least 30 minutes).
3.
Use a slightly moistened cloth to clean the outer surface of the luminaire. Do not use any
aggressive cleaners. Avoid getting water inside the unit and on the electric components.
SHIELD
Do not use the product, if the protective shield is cracked or broken! Disconnect it from the
power network, after it has been unpowered! For replacing the protective shield, remove the
device from the wall. Remove the screws from the back of the product, then replace the
shield. Assemble the floodlight and install it again.
WARNINGS
• Make sure, the appliance has not damaged during transport!!
• Installation should only be performed by a specialist, in compliance with the safety
and contact protection regulations in force.
• Device may only be mounted on a surface which has sufficient bearing capacity, at
least 1,8 m but maximum 5 m high from the floor level.
• Luminaire may only be used together with the protective shield!
• Broken shield has to be replaced!
• LED light source of the luminaire is not replaceable. At the end of the lamp lifespan
the entire luminaire should be destroyed.
• The luminaire is not suitable for looping-in installation.
DO NOT DARE INTO THE LIGHT OF THE LED!
R
EPLACE BROKEN SHIELD!
PLEASE MAINTAIN THE REQUIRED DISTANCE FROM
THE ILLUMINATED SURFACE (AND SHOULD BE 0,5 M)!
CAUTION: RISK OF ELECTRIC SHOCK!
Do not attempt to disassemble o
r
modify the unit or
its accessories. In case any part is damaged,
immediately power off the unit and seek the
assistance of a specialist.
THE POWER CABLE IS NOT REPLACEABLE. IF IT
BECOMES DAMAGED, THE PRODUCT SHOULD BE
DISCARDED.
Waste equipment must not be collected separately or disposed of with
household waste because it may contain components hazardous to the
environment or health. Used or waste equipment may be dropped off free of
charge at the point of sale, or at any distributor which sells equipment of
identical nature and function. Dispose of product at a facility specializing in the
collection of electronic waste. By doing so, you will protect the environment as
well as the health of others and yourself. If you have any questions, contact the
local waste management organization. We shall undertake the tasks pertinent
to the manufacturer as prescribed in the relevant regulations and shall bear any
associated costs arising.
SPECIFICATIONS
power supply: . . . . . . . . . . . . . . . . 230 V~ / 50 Hz
power: . . . . . . . . . . . . . . . . . . . . . 10 W
luminous intensity: . . . . . . . . . . . . . 800 lm
colortemperature:. . . . . . . . . . . . . . 4500 K
power factor: . . . . . . . . . . . . . . . . .
>
0,5
Meaning of IP65: . . . . . . . . . . . . . Protected from ingress of dust.
. . . . . . . . . . . . . . . . . . . . . . . . . .
Protected from waterjet
. . . . . . . . . . . . . . . . . . . . . . . . . .
(from all direction).
operating temperature: . . . . . . . . . -20 - +40 °C
weight: . . . . . . . . . . . . . . . . . . . . 4
75
g
dimensions: . . . . . . . . . . . . . . . . . 115 x 190 x 120 mm
2
largest projection: . . . . . . . . . . . . . 1
91
cm
Motion sensor:
detection angle: . . . . . . . . . . . . . . . 120° in hand fan shape
sensing distance:. . . . . . . . . . . . . . approx. 4-12 m (<24 °C)
operating time:. . . . . . . . . . . . . . . . 10 mp – 4 perc
light sensitivity: . . . . . . . . . . . . . . . 10-20.000 LUX
LED floodlight
0,5 m
FLP 10 LED
L –
Live: brown or black wire
N –
Neutral: blue wire
–
Grounding: green-yellow wire
Malfunction
The lamp does not turn on when
motion is detected.
Sensitivity is weak.
The motion sensor does not turn
the device off.
Solution
Check the wiring and the power supply.
Make sure the adjusted light sensitivity is correct
.
Make sure that nothing covers the motion sensor's
window, and it is clean.
It is possible that the ambient temperature is too
high.
Check if there is an induction signal source in the
motion detection area. (eg. electric motor)
Check the installations height.
Make sure that the direction of the motion which
the device is trying to detect is correct.
Verify if there is continuous infrared signal source
in the detection area.
Verify if the delay time is set to the maximum.
Make sure the mains voltage is 230 V~ / 50 Hz
Check if the temperature is not changing too ofter
nearby the device (eg. due to an air conditioner or
a radiator) .
EN