INSTALLATION

1. Before switching on for the first time, carefully remove the packaging material taking care not to 

damage the appliance and power cable. Do not use the product if it is damaged in any way.

2. The unit may only be used indoors in dry conditions.

3. The free flow of warm air must be ensured for proper operation, therefore, please select the location 

for wall mounting according to 

Figure 2.

 Do not locate the appliance directly below a wall outlet.

4. In order to insert the wall studs, drill holes of appropriate size into the wall, at least 180 cm from the 

floor, along a horizontal line and 38,5 cm from each other.

5. Insert the studs into the holes then drive the enclosed screws into the studs so that the screw heads 

extend approx. 10 mm from the wall surface.

6. Hang the unit's rear panel onto the screw heads, moving it slightly to the right then down. Confirm 

that the heater is hanging securely on the wall.

7. Plug the unit's standard grounded AC power cable into a grounded wall outlet.

8. 

Please insert 1 pc CR2025 battery in the remote control. Please pay attention on right polarity. After 

this your device is ready to use.

Caution:  Risk  of  electric  shock! 

Do  not  attempt  to  disassemble  of  modify  the  unit  or  its 

accessories. In case any part is damaged, immediately power off the unit and seek the assistance of 

a specialist.

In the event that the power cable should become damaged, it should only be replaced by the 

manufacturer, its service facility or similarly qualified personnel.

Meaning of symbol on appliance: 

Do not cover!

Covering the unit can cause overheating, fire or electric shock!

FEATURES

wall-mountable PTC* fan heater for heating the atmosphere of indoor premises selectable power output (1000 / 2000W) operating modes: cold, warm and hot air overheating protection 7,5-hour timer  indicator LEDs  remote 

 • 

 • 

 • 

 • 

 •  

 • 

controller

ASSEMBLY (Figure 1)

1. cold air inlet • 2. heated air outlets • 3. ON/OFF switch, heating stage selector • 4. timer control • 5. IR remote sensor • 6. temperature control • 7. combo LCD display • 8. power cable • 9. mounting points • 10. screws & studs

 • 11. 

ON/OFF switch • 12. heating stage selector • 13. timer control • 14. temperature control

OPERATION 

The unit can be operated by both the remote controller and the buttons located on the control panel.
When connected to a wall socket, it beeps shortly, and HOLD LED indicates that the unit is powered up, and ready for operation.

Function of the Buttons on the Unit:

Press button     to switch on the FAN mode. Then, you can select the heating level using the MODE button on the unit. The modes are I (1000 W), II (2000 W), and by pressing the button the third time, you will return to fan only 
mode. By pressing the TIMER button, you can set the operating time in 0.5 hour steps up to 7.5 hours. The TIMER setting is cleared, when the unit is switched off.
You can switch off the unit during operation at any time by pressing the button      . The unit will continue to operate for about 30 seconds in FAN mode, and then, it will beep shortly, and switch off.
Do not disconnect the unit, until it stops completely. This may cause damage to the unit!

Function of the Buttons on the Remote Controller:

Button       : 

 

On/off switch, and selection of the FAN mode

TIMER: 

 

See the button TIMER of the unit.

1000 W, 2000 W: 

Selection of the appropriate heating level.

In the event of overheating, the 

overheating protection

 function will switch off the unit, for example, when the air inlets and outlets are covered. Power off the unit by unplugging it from the electric outlet. Allow the appliance to 

cool (for at least 30 minutes). Check whether the air inlets and outlets are obstructed or not, and clean them if necessary. Switch on the unit again. If the overheating protection activates again, power off the unit by unplugging it 
from the electric outlet and contact the service facility.

C

LEANING & MAINTENANCE

In order to ensure optimum functioning, the unit may require cleaning at least once a month, depending on the manner of use and degree of contamination.
1. Switch off and power off the unit by unplugging it from the electric outlet prior to cleaning. 
2. Allow the appliance to cool (for at least 30 minutes).
3. Use a vacuum cleaner with a brush attachment to clean the air inlet and outlet openings.
4. Use a slightly moistened cloth to clean the unit’s exterior. Do not use any aggressive cleaners. Avoid getting water inside of and on the electric components of the appliance.

T

ROUBLESHOOTING

DISPOSAL

This symbol of the crossed out wheeled bin – on the product or its packaging – indicates that the product should not be placed in municipal waste. 

The appliance should be taken to a waste collection site licensed to collect waste electronic and electric equipment (WEEE) or the local waste management facility.

By doing so, you will protect the environment as well as the health of others and yourself.

For more information about recycling this equipment, please contact your local government, household waste disposal service or shop where you purchased

 the equipment.

Battery disposal

Do not dispose of used batteries with normal communal waste. The user is obliged under law to take any used or dead batteries to the local collection facility or point of original purchase. 

This allows the environmentally friendly disposal of batteries.

SPECIFICATIONS

p

ower supply:

. . . . . . . . . . .

230V / 50 Hz

r

ated power:

. . . . . . . . . . . .

1000 / 2000 W

m

ax. output:

. . . . . . . . . . . .

2000 W

IP protection:

. . . . . . . . . . .

IP20: Not protected from ingress of water.

s

ize of heater:

. . . . . . . . . . . 45 

x

 18,5 

x

 11,5

 cm

w

eight:

. . . . . . . . . . . . . . . . 1,7

 kg

l

ength of power cable:

. . . .

1,

6

 m

s

ound pressure: . . . . . . . . .

)

52

 dB(A

* The PTC (Positive Temperature Coefficient) is a ceramic polycrystalline semiconductor doped with barium and titanium. Its true advantage lies in that it possesses no 
temperature self-regulation properties so no precautions need to be taken against overheating, in addition to the unit being significantly energy efficient.

Solution

check the section on overheating protection
clean the appliance
check the remote controller batteries

Cause

The unit does not heat in heating mode
The overheating protection activates frequently
The unit does not respond to the remote controller’s signal

Summary of Contents for home FKF2000LED

Page 1: ...re uputstvo za upotrebu uputstvo za upotrebu navodilo za uporabo navodilo za uporabo n vod k pou it n vod k pou it instrukcja u ytkowania instrukcja u ytkowania uputa za uporabu uputa za uporabu erede...

Page 2: ...IVER 1 6 2 MODE FAN 4h 2h 1h 0 5h HOLD TIMER RECEIVER 7 10 8 9 11 MODE FAN 4h 2h 1h 0 5h HOLD TIMER RECEIVER 3 4 5 12 14 13 1000W 2000W figure 1 Abbildung 1 1 bra 1 obraz figura 1 1 skica 1 skica 1 ob...

Page 3: ...ttention Theunitdoesnotinclude a thermostat for the detection of the ambient temperature Do not use it in a small room if there are people inside who cannot leave the room by themselves unless constan...

Page 4: ...operationatanytimebypressingthebutton Theunitwillcontinuetooperateforabout30secondsinFANmode andthen itwillbeepshortly andswitchoff Donotdisconnecttheunit untilitstopscompletely Thismaycausedamagetoth...

Page 5: ...en Thermostat der die Raumtemperatur feststellt Nicht in kleinen R umen verwenden wenn sich dort Personen aufhalten die nicht imstande sind den Raum allein zu verlassen ausgenommen den Fall dass eine...

Page 6: ...hDr ckender Tasteausschalten DasGer tl uftdanninderBetriebsartVentilatornochca 30Sekundenweiter dannpieptkurzundschaltetaus TrennenSiedasGer tnichtvomStromnetz bisesvonsichselbststoppt daeszuSch dende...

Page 7: ...okozhat 8 Figyelem Ez a k sz l k nem tartalmaz a szoba h m rs klet t rz kel termoszt tot Ne haszn lja kis helyis gekben ha azokban olyan szem lyek tart zkodnak akik magukt l k ptelenek a helyis g elha...

Page 8: ...gnem lllemag t lak sz l k addigne ramtalan tsaazt mertazk ros thatjaak sz l ket At vir ny t gombjainakfunkci i gomb Ak sz l kki bekapcsol sa illetveaFAN ventil tor zemm dkiv laszt sa TIMER L sdk sz l...

Page 9: ...mal ch miestnostiach je dovolen iba v pr padoch ak s tak to osoby pod st lym dozorom 9 Pr stroj je ur en v lu ne na ohrievanie vzduchu pou vanie na in ohrievacie ely je zak zan 10 Dbajte o to aby tep...

Page 10: ...tedypr stroje teprev dzkuje30min tvre imeventil tora potomvyd vakr tkyzvukov sign lavypnesa Neodpojtepr strojodelektrickejsiete k msanevypnes m abysapr strojnepo kodil Funkciedia kov hoovl da a Tla id...

Page 11: ...ul n nc peri mici dac acolo sunt persoane care sunt n imposibilitatea de a p r si sala cu excep ia cazului n care supravegherea continu este asigurat 9 Aparatul poate fi folosit doar conform destina i...

Page 12: ...re tedinfunc ionarenu ldeconecta idelare eapentruc astfelpute ideterioraprodusul Func iilebutoanelortelecomenzii butonul Pornirea oprireaaparatului respectivselectareamoduluidefunc ionaretipventilator...

Page 13: ...tejeumalimprostorijamaukolikounjimaboravenemo neosobekojesamenemogu da napuste prostoriju izuzev u slu ajevima ako postoji konstantan nadzor 9 Ure aj je predvi en isklju ivo za zagrevanje vazduha pros...

Page 14: ...emeradaod0 5pa akdo7 5 sati Utokuradasetasterom bilokadamo eisklju itiure aj ventilator eidaljeraditijo 30sekundidabiseure ajohladio Dokseure ajneugasisamneisklju ujtegaizmre e tomo edao tetiure aja F...

Page 15: ...nih prostotih v kolikor v njih bivajo nemo ne osebe kateresamenemorejozapustotiprostora razenvprimerih eobstajastalennadzor 9 Napravaje predvidena izklju no za segrevanje zraka prostora za druge namen...

Page 16: ...vljalculahkokadarkoli izklju itenapravo ventilatorbo enaprejdelovalcca30sec doklersenapravaneohladi Doklersenapravaneugasnesamajeneizklju ujteizelektri nemre e tolahkopo kodujenapravo Funkcijskatipkov...

Page 17: ...imkou situace kdy maj zaji t n st l dozor 9 P stroj lze pou vat v hradn k oh v n vzduchu podle p vodn ho ur en nen dovoleno pou vat za elem b n ho vyt p n 10 Proud c tepl vzduch nesm b t nasm rov n be...

Page 18: ...skneavypnese Dokudsep strojs mnezastav neodpojujtejejzes t totom ezp sobit kodynan m Vtutodobuventil torje t 30vte inpracuje pakkr tcep skneavypnese Dokudsep strojs mnezastav neodpojujtejejzes t mohl...

Page 19: ...szczeniu Nie u ywaj urz dzenia w ma ych pomieszczeniach je eli przebywaj w nich osoby kt re same nie s w stanie opu ci pomieszczenia chyba e zapewnisz im sta y nadz r 9 Urz dzenie jest przeznaczone do...

Page 20: ...dziejeszczepracowa wtrybiewentylacjiprzezoko o30sekund anast pniewyemitujekr tkid wi kiwy czysi Dop kiurz dzenieniezatrzymasi samo nienale ygowy cza zgniazdka botomo espowodowa uszkodzenie Funkcjepil...