background image

KKER9C02-A0-page 9

0

~2

0

~999.9

0

~999.9

0

~1

0

~99

0

~99

0

~68

0

~2

0

~999.9

0

~999.9

0

~999.9

0

~10

0

~1

0

~999.9

0

~999.9

0

~999.9

0

~1

0

~99

0

~99

1

~32

1

/K/M

0

~999.9

0

~999.9

0

~3

0

~3

0

~3

0

~3

0

~3

0

~95

0

~95

0

~95

0

~95

0

~95

select 12/24

set correct time

1

~32

1

/K/M

0

~68

7

4

5

6

3

 Mode

 year  month   day   hour   minute second

1

2

3

7

8

1

2

3

7

8

Initial

8

Alarm Set

Alarm 1

Alarm 4

 mode  

 unit 

 value  

 backlash  

output

ON-DLY

OFF-DLY

When value is 0 , it is for remote control mode, otherwise it is for alarm mode. Please refer to table 1.

1: international standard unit,  K: 1000 times standard unit,  M: means1000000 times standard unit. 

1st alarm value setting
1st alarm hysteresis value setting

1st alarm relay output setting

alarm start delay time , unit : second

alarm finish delay time , unit : second

 mode  

 unit 

 value  

 backlash  

output

ON-DLY

OFF-DLY

When value is 0 , it is for remote control mode, otherwise it is for alarm mode. Please refer to table 1.

1: international standard unit,  K: 1000 times standard unit,  M: means1000000 times standard unit. 

4th alarm value setting

4th alarm hysteresis value setting

4th alarm relay output setting

alarm start delay time , unit : second

alarm finish delay time , unit : second

Trans Set

Please refer to table 1

Unit

High

Low

1: international standard unit,  K: 1000 times standard unit,  M: means1000000 times standard unit. 

Transmit output 20mA

Transmit output 4mA

Trans 1

Trans 2

can be ordered

Please refer to table 1

 Mode

Unit
High

Low

1: international standard unit,  K: 1000 times standard unit,  M: means1000000 times standard unit. 

Transmit output 20mA

Transmit output 4mA

Time set

time mode Date-time

time mode

24 hours

Tariff Setting

tariff

start time

calibrate

Period 1 tariff means tine tariff, Peak tariff, flat tariff, vale tariff

Period 2 tariff means tine tariff, Peak tariff, flat tariff, vale tariff

Period 3 tariff means tine tariff, Peak tariff, flat tariff, vale tariff

Period 7 tariff means tine tariff, Peak tariff, flat tariff, vale tariff

Period 8 tariff means tine tariff, Peak tariff, flat tariff, vale tariff

Period 1 start time
Period 2 start time
Period 3 start time

Period 7 start time

Period 8 start time

System Set

Volt min

Cur. Min

Comm. delay
Energy Mode

set minimum value of voltage
set minimum value of current
set communication delay , unit:ms

energy calculation mode . 1 means primary calculation. 2 means secondary calculation

Extend 1

Extend 2

Extend 3
Extend 4

for spare

for spare

for spare

for spare

Clr. Kwh

Clr. Demand

reset to factory default setting

clear kwh
clear demand

Clr. Event

clear event

password

factory setting , not opened

    

Divide 24 hours a day into 96 segments, every 15 minutes as one segments. For example, the corresponding time for segment 0 is 0 o'clock, 

the corresponding time for segment 10 is 2:30. Please notice that,  the setting of period 1 to period 12 should be from small to big. 

Note

Summary of Contents for ER9 Series

Page 1: ...n may lead to product damage The instruction of the symbol in the manual is as below An accident danger may happen in a special condition 1 A safety protection equipment must be installed or please contact with us for the relative information if the product is used under the circumstance such as nuclear control medical treatment equipment automobile train airplane aviation entertainment or safety ...

Page 2: ...oltage impedance 300KΩ Voltage Accuracy RMS measurement Accuracy 0 5 AC 0 025 5A Current Range Current Overload Continuous 1 2 times Instantaneous 4 times 10S Current Consumption 0 4VA each phase Current impedance 20mΩ Current Accuracy RMS measurement Accuracy 0 5 Energy Active energy accuracy 0 5 Reactive energy accuracy 1 Power Active power Reactive power Apparent power accuracy 0 5 Display TFT ...

Page 3: ...e input voltage is corresponding to the input current they should have the same phase sequence and direction otherwise data and sign error may occur power and energy D The connection mode of meter which is connected to power network should depend on the CT quantity For 2pcs of CT it should be 3 phase 3 wire connection For 3pcs of CT it shoud be 3 phase 4 wire connection E Please pay high attention...

Page 4: ...nstantaneous parameters energy harmonics measurement tariff rate kwh energy record event record and meter setting and display setting in guide pages to move cursor Press to enter subpages accordingly In electrical energy harmonic tariff record and event page press to back to guide page In meter set and display set interface press to guide page interface ...

Page 5: ...ift the page In any pages press to back to guide page In the bottom of display interface there is press key operation remind Energy Interface Operation SET In energy interface press key to shift the page In any pages press to back to guide page In the bottom of display interface there is press key operation remind ...

Page 6: ...age In the bottom of display interface there is press key operation remind In any page press to back to guide page Note This function is not available now SET In tariff interface press key to shift the page In any pages press to back to guide page In the bottom of display interface there is press key operation remind ...

Page 7: ... the page Press to back to guide page In the bottom of display interface there is press key operation remind SET In electrical interface press key to shift the page In any pages press to back to guide page In the bottom of display interface there is press key operation remind 1 realtime curve display operation ...

Page 8: ... box press or to select to delete cancel or modify operation After finishing value modification press to confirm and exit the interface It will appear whether save the dialog box select yes to storage the value and exit to return the operating menu Press to move to password cursor press password press to confirm to enter configuration set interface No class 1 class 2 description range Signal set L...

Page 9: ...unit Transmit output 20mA Transmit output 4mA Trans 1 Trans 2 can be ordered Please refer to table 1 Mode Unit High Low 1 international standard unit K 1000 times standard unit M means1000000 times standard unit Transmit output 20mA Transmit output 4mA Time set time mode Date time time mode 24 hours Tariff Setting tariff start time calibrate Period 1 tariff means tine tariff Peak tariff flat tarif...

Page 10: ...S PFa PFb UcL UL UabL UcH UH UabH Ubc Uca UL Ia Ib Ic I Pa Pb Pc P Qa Uc U Uab Reference table 1 Reference table for alarm output and transmit output No Parameter switch output code low alarm switch output code high alarm transmit output code 4 20mA Ua A phase voltage Ub B phase voltage Uc C phase voltage U phase voltage of A B or C Uab AB line voltage Ubc BC line voltage Uca CA line voltage UL li...

Page 11: ...monthly report form 5 Backup file name present data file serial number 6 Backup the file to USB or SD card 7 Backup progress bar and backup status display SET ESC 1 Confirm USB or SD card connect well with power recorder check the SD card or USB status remind on the status bar 2 Set backup data start time 3 Set backup data finish time 4 Set the backup file content 5 Confirm the file name file name...

Page 12: ... 100 and 0 Each phase power factor low and high limit default setting is 1 and 0 From Data backup start time Data backup end time to Backup file name backup to USB backup to SD backup to USB backup to SD record kwh everyday record kwh every month record kwh everyday record kwh every month number ok number ABC abc piny There are three type modification adjust input parameter edit input parameter se...

Page 13: ...rid easy for check record curve in each grid or layout 4 A phase real time record curve the color is the same with A phase measuring data 5 B phase real time record curve the color is the same with B phase measuring data 6 C phase real time record curve the color is the same with C phase measuring data 1 Display history record interface name data and time 2 Data recall mode recall mode and cursor ...

Page 14: ...qual to 1kwhX voltage transform PT X current transform CT 2 Remote measure and remote control function 4 loops S1 S4 are used to remote measure electric ON OFF status DO1 DO2 function can be used to remote control electric devices When using Do function alarm mode should be setted as 0 otherwise DO1 and DO2 will be as AL1 AL2 output DO1 DO2 function control value is writen via RS485 interface 3 Co...