Rollixo RTS
Copyright © 2012 Somfy SAS. All rights reserved
11
EN
ChECkING oPERAtIoN of thE RECEIvER
operation in sequential mode
STOP
STOP
STOP
Integrated lighting
The lamp comes on each time a command is sent to the receiver.
It goes out 2 minutes after the door stops.
orange light
The orange light flashes every time the receiver is controlled, with or without a 2-second warning, depending on the configured parameter setting.
It stops flashing when the door stops.
Cells
If the cells are blocked when the door is closed, it stops, then re-opens fully.
If the cells are blocked when the door is opened, the door continues its movement.
safety edge
If the safety edge is activated when the door is closing, it stops then re-opens partially.
If the safety edge is activated while the door is opening, it continues its movement.
Alarm (optional)
The alarm is triggered for 2 minutes if the door is fully closed and raised manually. No movement of the door is possible when the alarm is sounding.
When the alarm sounds, press a button on a remote control memorised in the receiver to stop it.
The alarm can only be stopped with a memorised remote control.