Indicator light status

Diagnostics

Consequences

Actions/troubleshooting

Prog

optical wired 

safety edge

Optical wired safety edge 

failure

Opening ok

Closed by pressing 

and holding down

-  Check the type of safety edge connected (optical wired 

safety edge, dipswitch no.4 set to OFF); if the wired safety 

edge is resistive, move dipswitch no.4 to ON.

-  Check the safety edge wiring (see page 14).

-  Check that no radio safety edge transmitter is memorised in 

the receiver. If a radio safety edge transmitter is memorised 

in the receiver, clear it (see page 19).

Resistive 

wired safety 

edge

Resistive wired safety 

edge failure

Opening ok

Closed by pressing 

and holding down

-  Check the type of safety edge connected (resistive wired 

safety edge, dipswitch no.4 set to ON); if the connected 

safety edge is resistive, move dipswitch no.4 to OFF.

-  Check the safety edge wiring (see page 14).

-  Check that no radio safety edge transmitter is memorised in 

the receiver. If a radio safety edge transmitter is memorised 

in the receiver, clear it (see page 19).

Radio safety 

edge

Radio safety edge failure Opening ok

Closed by pressing 

and holding down

See radio safety edge transmitters for diagnostics (see pages 

20 and 21).

Repeat the safety edge transmitter memorisation procedure 

on the receiver (see page 18).

Radio interference on the 

safety edge transmitter

Opening and 

stopping ok

Closed by pressing 

and holding 

down: the closing 

movement will 

automatically 

resume when the 

radio interference 

disappears.

If a powerful radio system is present on the site (infrared 

detector, TV transmitter, etc.) and is transmitting on the same 

frequency, the receiver will wait for the transmission to end to 

before controlling the door again.

Magnets missing if the 

resistive safety edge 

transmitter is installed

Opening ok

Closed by pressing 

and holding down

Check for the presence of magnets and install them if required 

(see pages 9 and 10).

End of life of the safety 

edge transmitter batteries

Opening ok

Closed by pressing 

and holding down

Safety edge transmitter low battery indication.

If the fault persists, replace the safety edge transmitter 

batteries.

Obstacle detection

Remove the 

obstacle by 

automatic partial 

opening

Check that no obstacle is causing the safety edge to detect.

Photoelectric 

cells

Cell fault

Opening ok

Closed by pressing 

and holding down

If no cells are installed, check that the connector (terminals 18 

and 19) is bridged.

If cells are installed:

 - Check that no obstacle is cutting across the cell beam 

 -  Check the position of dipswitch no.2 in accordance with the 

type of cell (see page 12).

 - Check the cell wiring (see page 13).

Bridged cell connector

Opening ok

Closed by pressing 

and holding down

If no cells are installed and cell connectors are bridged 

(terminals 18 and 19), check that dipswitch no.1 is set to OFF.

Obstacle detection

Remove the 

obstacle by full 

automatic opening

Check that no obstacle is cutting across the cell beam

Radio

Radio frame received from 

a recognised transmitter

Resistive safety edge transmitter (EsE)

Press the button on the back of the transmitter once.
The transmitter indicator light will come on:

If the indicator light flashes: 
6 times → the safety edge is faulty (short-circuit).
8 times →  the safety edge has not been correctly lengthened (open circuit).

Summary of Contents for Rollixo RTS

Page 1: ...EN Installation XLGH ROLLIXO RTS 3 4 2 1 Prog STOP ...

Page 2: ...edge and its transmitter 10 Recognising magnets 10 Checking operation of the receiver 11 Operation in sequential mode 11 Integrated lighting 11 Orange light 11 Cells 11 Safety edge 11 Alarm optional 11 Connecting additional devices 12 General wiring diagram 12 Wiring option parameter setting 12 Description of the various additional devices 13 Advanced parameter setting 16 Different operating modes...

Page 3: ... be installed is 1 5 m and they must not be accessible to the public Place the fixed control devices and remote controls out of the reach of children The safety instructions must be followed throughout the installation Take off any jewellery bracelet chain etc during installation For drilling and welding operations wear special glasses and appropriate protection Use the appropriate tools Be carefu...

Page 4: ...13 Description of the external programming interface No Description Function 1 Up button Opening the door 2 STOP Button Stopping the door 3 Down button Closing the door 4 Prog Button Programming radio transmitters 5 Prog Indicator light Information on radio reception and programming radio transmitters 6 Motor and fall protection warning light Information on the status of the motor and fall protect...

Page 5: ...A 2 m mains power cable is supplied with the receiver It is advisable to install the receiver on the same side of the door as the safety edge transmitter 1 Remove the integrated light bulb 2 Unscrew and remove the receiver cover 3 Hold the receiver against the wall lighting facing upwards and line up with drilled holes 4 Mount the receiver onto the wall ...

Page 6: ...tion wiring If no fall protection is connected it is essential to create the bridge between terminals 5 and 6 of the receiver with the shunt provided 2 Lock the motor cable with the cable clamp provided The motor cable must be placed in the receiver s 230 V insulation area Motor wiring 1 Connect the motor to the receiver Note the motor s direction of rotation shall then be checked and reversed if ...

Page 7: ...ver 4 Refit the integrated lighting bulb 5 Connect the receiver to the mains power supply All the indicator lights come on and then go out If indicator light 1 comes on permanently fall protection is not connected or incorrectly connected to the receiver If indicator light 2 comes on permanently the safety edge has not been detected by the receiver radio safety edge transmitter not yet memorised o...

Page 8: ...or light 1 flashes slowly 3 4 2 1 Prog STOP 3 4 2 1 Prog STOP Correct direction of rotation Incorrect direction of rotation 3 If the motor end limits are already set move on to step 8 to exit motor adjustment mode If the motor end limits are not set check that the motor is released the two push buttons should be pressed Note The motor end limits can also be set with a setting tool ref 9015971 In t...

Page 9: ...OP or or 3 4 2 1 Prog STOP 3 4 2 1 Prog STOP 7 Press the motor s low end limit push button 8 Press simultaneously on the and buttons or press the Prog button until the motor s up and down movement occurs to enter motor adjustment mode Indicator light 1 goes out 3 4 2 1 Prog STOP ...

Page 10: ...ly 2 Using the tip of a pen press the transmitter PROG push button for 4 seconds Indicator light 2 on the receiver goes out and the receiver s Prog indicator light will flash and then go out this may take a few seconds the time required for the transmitter and receiver to communicate with each other The transmitter is memorised in the receiver Installing the safety edge and its transmitter Follow ...

Page 11: ...e is observed to ensure completely safe operation of the door The door must be in the intermediate position before the magnet recognition procedure can be started Do not press the safety edge during the magnet recognition procedure Carry out two whole cycles opening then closing using buttons and 10 mm maxi 4 Attach the magnet to the edge of the runner positioning it in line with the transmitter T...

Page 12: ...ls If the cells are blocked when the door is closed it stops then re opens fully If the cells are blocked when the door is opened the door continues its movement Safety edge If the safety edge is activated when the door is closing it stops then re opens partially If the safety edge is activated while the door is opening it continues its movement Alarm optional The alarm is triggered for 2 minutes ...

Page 13: ...d NO contact 12 13 24 Vdc 0 Vdc 24V 3 5 W orange light output Maximum 4 W bulb 14 15 24 Vdc 0 Vdc TX cell 24 V power supply Transmitting photoelectric cell Reflex photocell power supply 16 17 18 19 20 24 Vdc 0 Vdc Shared Contact Test output RX cell 24 V power supply Cell safety input NC Cell safety test output Receiving photoelectric cell power supply Reflex photocell self test 22 433 42 MHz aeria...

Page 14: ...able to see it automatic closure is activated Reflex photocell Note In accordance with standard EN 12453 governing the safe use of motorised gates and doors the use of the TAHOMAcontrol box to automatically control a garage door or gate not visible to the user requires the installation of a photoelectric cell type safety device with autotest on the automatic control system Receiver Cell Comments D...

Page 15: ... 7 8 9 10 11 1 Brown Brown Brown White White White Green Green Green Dipswitch 4 receiver position Dipswitch 4 receiver position If a wired safety edge replaces a radio safety edge the radio safety edge transmitter must be cleared see page 18 to ensure the wired safety edge is taken into account If a wired safety edge replaces a radio safety edge the radio safety edge transmitter must be cleared s...

Page 16: ...arm Mount the alarm to the receiver with the bolt provided Connect the alarm connector Activating Deactivating the alarm Dipswitch 5 receiver set to ON Alarm activated Dipswitch 5 receiver set to OFF Alarm deactivated or not connected Alarm operation The alarm is triggered for 2 minutes if the door is raised manually No movement of the door is possible when the alarm is sounding When the alarm sou...

Page 17: ...by default If there is an obstacle in the cells detection zone the door will not close It will close once the obstacle is removed Note by default no automatic closure option for the door is activated The installation of photoelectric cells is mandatory in the event that an automatic closure option is activated Programming operating modes Changing the operating mode Advanced parameter setting Modif...

Page 18: ...Prog Prog Prog Prog 1 1 2 2 Memorising 3 button remote controls 1 Press button Prog on the receiver until the indicator light above it comes on permanently 2 Press the PROG button on the back of the remote control to be memorised within a maximum of 2 minutes The indicator light above button Prog on the receiver flashes the remote control is memorised in the receiver Memorising by copying a previo...

Page 19: ... comes on with each press and after the 5th press remains constantly lit for 4 seconds and then flashes for 4 seconds Indicator light 2 on the receiver goes out and the receiver Prog indicator light will flash and then go out this may take a few seconds the time required for the transmitter and receiver to communicate with each other The transmitter is memorised in the receiver 3 Restart the magne...

Page 20: ... motor end limits see pages 7 and 8 Receiver Indicator light status Meaning Off Functional installation Slow flashing Waiting for an action adjustment Rapid flashing Deactivation activation in progress Permanently lit Installation fault failure Clearing safety edge transmitters Press button Prog on the receiver for approximately 14 s until the indicator light above it goes out Release button Prog ...

Page 21: ...tem is present on the site infrared detector TV transmitter etc and is transmitting on the same frequency the receiver will wait for the transmission to end to before controlling the door again Magnets missing if the resistive safety edge transmitter is installed Opening ok Closed by pressing and holding down Check for the presence of magnets and install them if required see pages 9 and 10 End of ...

Page 22: ...onger operating and must be replaced ref 1781245 Follow the instructions provided with the OSE transmitter then carry out commissioning as described on page 9 Open the OSE transmitter housing Press button SW2 until LED 1 lights up permanently red LED 1 and LED 2 remain off LED 1 and LED 2 light up red briefly Check that the rubber on the safety edge is not crushed and repeat the check Check the ph...

Page 23: ...Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 09 2012 Somfy Ltd Moorfield Road Yeadon Leeds West Yorkshire LS19 7BN T 0113 391 3030 www somfy co uk www rollixo co uk ...

Reviews: