2. 4. TIPS AND ADVICE ON INSTALLATION
2. 4. 1. Questions about the drive?
Observations
Possible causes
Solutions
The driven product
does not operate.
The wiring is incorrect.
Check the wiring and modify as required.
The drive’s overheating protection
has tripped.
Wait for the drive to cool down.
The cable used is not compliant.
Check the cable and make sure that it has
3 conductors.
The Somfy io control point battery
is low.
Check the battery and replace it as required.
The control point is not compatible.
Check the compatibility and replace the
control point as required.
The Somfy io control point being used
is not programmed in the drive.
Use a programmed control point or
program this control point.
The driven product
stops too soon.
The ring is not correctly installed.
Secure the ring correctly.
The end limits are incorrectly
programmed.
Reset the end limits.
2. 4. 2. Re-setting the end limits
The following steps apply only for end limits that are set manually.
` `?
A. READJUSTMENT OF END LIMITS SET IN MANUAL MODE
1)
Place the driven product in its end limit position to be
2)
Press and hold the “Up” and “Down” buttons
simultaneously for 5 seconds until the driven product
`
3)
Place the driven product in its new end limit position
using the “Up” or “Down” buttons.
4)
To validate the setting, press the “my” button until the
`
B. READJUSTMENT OF THE LOCKING SYSTEM AT THE LOWER END
LIMIT
1)
Place the driven product at its lower end limit.
2)
Press and hold the “Up” and “Down” buttons
simultaneously for 5 seconds: the driven product
`
3)
Press the “Down” button: the driven product lowers.
4)
Press the “my” button to stop the product at position
(P1), which corresponds to the locking system’s
entrance point.
5)
Press the “my” and “Up” buttons simultaneously: the
driven product raises and stops, putting tension on
the fabric.
6)
Press the “Down” button: the driven product lowers.
7)
Press the “my” button to stop the driven product
at position (P2), which corresponds to the locking
system’s exit point.
8)
To validate the setting, press the “my” button again
?
`
1)
3)
4)
5 sec.
2)
5 sec.
1)
2)
P1
P1
P2
P2
3)
4)
7)
5)
6)
P1
P2
P1
P2
P1
P2
P1
P2
8)
Summary of Contents for MAESTRIA Plus 50 io
Page 1: ...MAESTRIA 50 io Ref 5123562A l6 g m FR Notice DE Anleitung NL Handleiding EN Instructions...
Page 2: ......
Page 27: ......