For demonstrating the control functions it is possible to shorten the
reaction times of the SOLIRIS IB.
To do this, the SOLIRIS IB can be switched to demo-mode. The maxi-
mum movement time from highest to lowest end position in demo-
mode is approx. 30 seconds. All other settings and programming will
be performed as previously.
SOLIRIS IB
6
Demo setting
4.4
4.4.1 Demo setting – awnings
In the awning demo setting, each time
or
are pressed this constitutes a move command.
Programming the awning demo setting
Press
for approx. 2 seconds. The red and yellow LEDs flash alternately. Then press
and
simultaneously until the yellow
LED lights up 4 times (twice briefly – pause – twice briefly).
➜
Awning demo setting is programmed.
MODE
MODE
4.4.2 Demo setting – venetian blind
In the venetian blind demo setting, each time
or
are pressed briefly this constitutes a move command.
For venetian blind operation, a slat tilting operation can be programmed (chapter 4.3).
Programming the venetian blind demo setting
Press Mode for approx. 2 seconds. The red and yellow LEDs flash alternately. Then press
and
simultaneously until the red LED
lights up 4 times (twice briefly – pause – twice briefly).
➜
venetian blind demo setting is programmed.
MODE
Test:
The programming of the operating mode can be tested as follows. Press
briefly
➜
the LED allocated to the set operating mode lights up twice briefly.
Yellow LED – awning demo setting
Red LED – venetian blind demo setting
Quitting demo mode
To quit the demo mode, program in the desired operating mode, as described in chapter 4.1
MODE
We reserve the right to make changes due to technical improvements.
Normal mode
Demo mode
SUN appearing :
2 min.
10 sec.
SUN disappearing :
15/30 min.
15/30 sec.
WIND appearing :
2 sec.
2 sec.
WIND disappearing : 30 sec. 12 min.
15 sec.
Output relays :
0,5 sec.
0,5 sec.
TIMINGS