background image

3

SOLIRIS IB

The sun control function can be turned on and off using the sliding switch:

Sun control 

ON :

the SOLIRIS IB reacts in accordance with the wind, the sun and with 
the manual UP/DOWN/STOP commands.

Sun control 

OFF :

the SOLIRIS IB reacts in accordance with the wind information and with the 
manual UP/DOWN/STOP commands.

The potentiometers allow the threshold values for brightness and wind speed to be set.

The wind and sun controls can be checked as follows

- Set the sun control sliding switch to Sun control ON :

.

- Set the wind potentiometer to 

5 km/h

and the Sun potentiometer to 

Test

position 

The yellow Sun LED shines continuously : The sun detection is working correctly

.

The red Wind LED is illuminated when the anemometer starts to rotate : The wind detection is working correctly.

5

20

40

60

max

km/h

kLux

20

35

50

max

Test

kLux

20

35

50

max

Test

5

20

40

60

max

km/h

Wind and sun controls

3.1

We reserve the right to make changes due to technical improvements. 

3

Settings:

MODE

UP button

LED red/green

Wind adjustment

Sun adjustment

LED yellow

SUN on/off switch

MODE button

STOP/IP button

DOWN button

All manual or
automatic
commands are
inhibited as long as the
wind speed is higher
than the adjusted
threshold.

When the wind
speed exceeds the
threshold set on
the SOLIRIS IB, the
red LED lights on
and  the awning is
retracted after 2
seconds.

When the wind
speed falls be-
low the threshold
setting, the red
LED begins to blink.
A manual control can be
given after 30 seconds and
an automatic sun control
can be given after 12 minutes.

after 12 min. after 30 sec.

Wind control operation

WIND

Wind speed setting range: 5-80 km/h
Factory setting: approx. 20 km/h

SUN

Brightness setting range: 20-60 kLux
Factory setting: approx. 35 kLux

after 2 secs.

When the daylight level falls below the threshold setting, the yellow
LED blinks and the awning is automatically retracted after a variable
timing between 30 to15 mins.
This timing depends on the sun presence duration and it avoids fre-
quent movements of the awning on cloudy days.
short period of sun (< 30’) 

➜ 

30 mins. before retraction.

long period of sun (> 90’) 

➜ 

15 mins. before retraction.

Moreover, If the daylight falls below 12 kLux, the timing is decreased
to approx. 5 minutes to retract the awning more quickly at twilight.

When the intensity
of the daylight ex-
ceeds the threshold
set by the SOLIRIS
IB, the yellow LED
lights on and a DOWN order is sent
to the awning after 2 minutes.
The awning goes to the intermediate position IP (see
4.2) or to its down end limit position if no intermediate
position has been memorised.

IP

after 30-15 mins. or 5 mins.

Sun control operation

Summary of Contents for Inteo SOLIRIS IB

Page 1: ...n is also possible and the sun function can be switched off If the wind is too strong the awning blind is automatically retracted and manual operation is blocked The wind function is a safety function and is always activated 220 240V 50 60Hz IP 40 II 5 C to 40 C dry living areas 500 mA 50VDC Setting up testing commissioning and troubleshooting for this equipment should only be car ried out by a tr...

Page 2: ...hase L Main Neutral N IB Bus common C IB Bus Up IB Bus Down Common C Sun sensor Wind sensor Rain sensor C Mounting 2 1 Soliris sensor Rain sensor Soliris IB Centralis uno IB Centralis uno IB 3x0 75mm 2 2x0 75mm 2 4x0 75mm 2 4x0 75mm 2 3x0 75mm 2 Supply 3x1 5mm2 Supply 3x1 5mm2 Supply 3x1 5mm2 Supply 3x1 5mm2 3x0 75mm 2 3x0 75mm 2 Centralis uno IB 4x0 75mm 2 Supply 3x1 5mm2 We reserve the right to ...

Page 3: ...ted threshold When the wind speed exceeds the threshold set on the SOLIRIS IB the red LED lights on and the awning is retracted after 2 seconds When the wind speed falls be low the threshold setting the red LED begins to blink A manual control can be given after 30 seconds and an automatic sun control can be given after 12 minutes after 12 min after 30 sec Wind control operation WIND Wind speed se...

Page 4: ...after 3 minutes or press the button Mode of operation 4 1 In awning mode each time or is pressed this constitutes a move command This mode is set by default in factory Programming awning mode Press for approx 2 seconds The red and yellow LEDs flash alternately Then press for approx 2 seconds until the yellow LED lights up briefly twice briefly once pause briefly once Awning mode is programmed MODE...

Page 5: ...enetian blind at its UP limit position blind retracted 2 Press The blind will move to the intermediate position the slats are closed 3 Press and simultaneously After approx 3 seconds the slats will momentarily move UP and the LED shines green 4 Adjust the right tiliting angle using and 5 Press for approx 2 seconds The green LED lights off the slat tilting procedure is now programmed Slat tilting 4...

Page 6: ...me or are pressed briefly this constitutes a move command For venetian blind operation a slat tilting operation can be programmed chapter 4 3 Programming the venetian blind demo setting Press Mode for approx 2 seconds The red and yellow LEDs flash alternately Then press and simultaneously until the red LED lights up 4 times twice briefly pause twice briefly venetian blind demo setting is programme...

Reviews: