background image

With this mode, your house appears to be inhabited during your absence, with the shutters opening and closing at random times.
The times deviate automatically from the weekly program input times within a window of  +/- 15 minutes.
Hold down 

until 

(SEC) 

is displayed.

Only manual move commands are executed.

press 

+

briefly with the 

➜ 

(OFF) 

is displayed.

press 

-

briefly with the  

➜ 

time is displayed.

+

-

+

-

The shutters open and close at approximately sunrise and sunset.
By inputting a differential time, opening and/or closing can be moved independently in relation to the times of sunrise and sunset
by up to +/- 1h 59 min.
By inputting individual blocking times, it particularly prevents very early or late move commands in the summer months.

Example: 

With +1h 

differential time

for UP, the shutters open 1 hour after sunrise. With -1h they open 1 hour before sunrise.

The sun rises shortly after 05:00 in June. However, you want your roller shutters to open at 07:00 at the earliest. Input the blocking time 07:00 for UP.
Sunset occurs at approx. 21:40. If you want your roller shutters to close at 21:00 at the latest, then input the 

blocking time

21:00 for DOWN.

The factory setting for the UP blocking time is 06:00, and 20:00 for DOWN. If you want these blocking times to have no effect on the opening or closing, and
the shutters to be controlled at the time of sunrise and sunset, then you can set the UP 

blocking time

to 05:00 and the DOWN 

blocking time

to 22:00.

Cosmic 2 always opens the roller shutters at the times set in the 

weekly program

and close them at the times from 

Cosmic 1

.

The differential time and the blocking time that were set in Cosmic 1 are taken into account. No changes can be made to the swit-
ching times in Cosmic 2.

Set differential time

1.

Hold

down until 

(COS 1)

is displayed.

2.

Press

briefly 

➜ 

time blinks and the next switching command is dis-

played.

3.

Press

briefly 

➜ 

differential time UP blinks.

4.

Change differential time “UP” with 

5.

Press

briefly 

➜ 

differential time “DOWN” blinks.

6.

Change differential time “DOWN” with 

7.

Press

briefly (store) 

➜ 

differential times are stored, time display.

+

-

+

-

The CHRONIS Uno offers five different operating modes, which can meet all personal requirements by pressing a button.

Security/holiday switching (SEC)

Cosmic 1 (COS 1)

OFF mode

Cosmic 2 (COS 2)

Configurations :

Weekly program (

▼ 

20:00)

The shutters are automatically opened or closed at the input opening and closing times.

The factory setting for opening is 06:00 and 20:00 for closing.

Different times can be input for each day of the week. The day of the week to which the time input applies is always shown blinking.

Changing the weekly program (if necessary):

1.

Hold 

down until the weekly program  (

▼ 

20:00) is displayed.

2.

Press

briefly 

➜ 

time blinks.

3.

Press

briefly 

➜ 

“UP” switching time blinks.

4.

Press

to select the day of the week you wish to program. You can also select all days of the week (1234567).

5.

Set “UP” switching time with 

6.

Press

briefly 

➜ 

“DOWN” switching time blinks.

7.

Set “DOWN” switching time with 

If required, set the next day with 

and repeat (3) to (7).

After input press

briefly (store) 

➜ 

time display.

If the “UP” or “DOWN” time is turned further than 23:59 with the 

, the display shows (OFF).

Automatic opening or closing can be deliberately switched off for “UP” and “DOWN” commands on individual days by using the OFF setting.

+

-

+

-

+

-

Set blocking time

1.

Hold

down until 

(COS 1)

is displayed.

2.

Press

briefly 

➜ 

time blinks and the next switching command is dis-

played.

3.

Press twice

briefly 

➜ 

blocking time “UP” blinks.

4.

Change blocking time “UP” with 

5.

Press twice

briefly 

➜ 

blocking time “DOWN” blinks.

6.

Change blocking time “DOWN” with 

7.

Press

briefly (store) 

➜ 

blocking times are stored, time display.

+

-

+

-

Summary of Contents for inteo CHRONIS UNO

Page 1: ...of 15 minutes around the programmed times Main supply 220 240V 50Hz Class II product Protection index IP40 Output 250V 3A cosφ 0 8 Output temporisation activ for 180s Environmental conditions for use temperature 5 C to 40 C no condensation allowed pollution degree typical for usual living space Time accuracy 5 minutes a year Power failure date and time are stored up to 10 days The memorized open a...

Page 2: ...me blinks Set time with Press briefly store time display stops blinking SET summer or winter time SET time 1 Press briefly date display if no input within 10 sec the display returns to the time 2 Press briefly day blinks 3 Set day with 4 Press briefly month blinks 5 Set month with 6 Press briefly year blinks 7 Set year with 8 Press briefly store year stops blinking time display The day of the week...

Page 3: ...t differential time 1 Hold down until COS 1 is displayed 2 Press briefly time blinks and the next switching command is dis played 3 Press briefly differential time UP blinks 4 Change differential time UP with 5 Press briefly differential time DOWN blinks 6 Change differential time DOWN with 7 Press briefly store differential times are stored time display The CHRONIS Uno offers five different opera...

Page 4: ... command By pressing briefly the or push buttons the shutter is activated in the corresponding direction By pressing briefly the push button the shutter stops Two different Drape modes can be set DEU Impulse control shorter than 2 seconds Blind activated during the time of pressing Control longer than 2 seconds Blind activated during 3 minutes USA Impulse control shorter than 0 5s Blind activated ...

Reviews: