background image

C

Intermediate positions (only for roller shutter) :

With the CHRONIS Uno, it is possible to set one or two intermediate positions (IP) : one accessible from the top of
the shutter and one from the bottom.
To record these positions, the CHRONIS Uno has to record the time for the roller shutter to go from its top to the
IP, and also the time from its bottom one to the IP.

RECORD THE INTERMEDIATE POSITIONS

• To reach one of the intermediate positions, press briefly the 
button of the CHRONIS UNO while the shutter is at its UP or DOWN
limits.

The shutter will move and stop at the dedicated intermediate

position.

®

Using:

Set the roller shutter to the end limit

.

Press briefly the 

button to reach the “IP”.

Press the 

button until “DEL” is shown instead of

the operating mode.

4

REPRODUCE THE INTERMEDIATE POSITIONS

DELETE AN “IP” WITHOUT MEMORIZING A NEW ONE

Set the DRAPE mode

Press simultaneoustly

and 

during 2s.

➜ 

(diA6) 

is displayed.

Press 

three times

briefly.

➜ 

(tiPP)

is displayed.

Change DRAPE mode with 

➜ 

DEU 

or

USA 

are displayed.

The CHRONIS Uno is initially configured to control a roller shutter but it is possible to configure the CHRONIS Uno
to control a VENETIAN blind (orientation of the slats).

MOVE / STOP command

By pressing briefly the 

or 

push buttons, the shutter is activated in the corresponding direction.

By pressing briefly the 

push button, the shutter stops.

Two different “Drape” modes can be set

DEU

Impulse control shorter than 2 seconds 

Blind activated during the time of pressing.

Control longer than 2 seconds 

Blind activated during 3 minutes.

USA

Impulse control shorter than 0.5s 

Blind activated during 3 minutes.

Control between 0.5s and 6s 

Blind activated during the time of pressing.

Control longer than 7s 

Blind activated during 3 minutes.

A

Roller shutter :

B

Venetian blind :

• Set the shutter at its 

UP

limit

with the 

push button.

1

• Push simultaneoustly on the

and 

button until the

shutter begins to move down
(about 3s).

after 

3 seconds

2

• Stop the shutter at the interme-
diate position you wish.
If necessary, adjust this position
with the push buttons.

3

• Push the 

button during two

seconds.

The CHRONIS Uno has memori-

zed the first intermediate position.

during
2 seconds

4

• Set the shutter at its 

DOWN

limit with the 

push button.

5

• Push simultaneoustly on the

and 

button until the

shutter begins to move up 
(about 3s).

after 

3 seconds

6

• Stop the shutter at the interme-
diate position you wish.
If necessary, adjust this position
with the push buttons.

7

• Push the 

button during two

seconds.

The CHRONIS Uno has memori-

zed the first intermediate position.

STOP

STOP

during
2 seconds

8

IP1

IP2

Summary of Contents for inteo CHRONIS UNO

Page 1: ...of 15 minutes around the programmed times Main supply 220 240V 50Hz Class II product Protection index IP40 Output 250V 3A cosφ 0 8 Output temporisation activ for 180s Environmental conditions for use temperature 5 C to 40 C no condensation allowed pollution degree typical for usual living space Time accuracy 5 minutes a year Power failure date and time are stored up to 10 days The memorized open a...

Page 2: ...me blinks Set time with Press briefly store time display stops blinking SET summer or winter time SET time 1 Press briefly date display if no input within 10 sec the display returns to the time 2 Press briefly day blinks 3 Set day with 4 Press briefly month blinks 5 Set month with 6 Press briefly year blinks 7 Set year with 8 Press briefly store year stops blinking time display The day of the week...

Page 3: ...t differential time 1 Hold down until COS 1 is displayed 2 Press briefly time blinks and the next switching command is dis played 3 Press briefly differential time UP blinks 4 Change differential time UP with 5 Press briefly differential time DOWN blinks 6 Change differential time DOWN with 7 Press briefly store differential times are stored time display The CHRONIS Uno offers five different opera...

Page 4: ... command By pressing briefly the or push buttons the shutter is activated in the corresponding direction By pressing briefly the push button the shutter stops Two different Drape modes can be set DEU Impulse control shorter than 2 seconds Blind activated during the time of pressing Control longer than 2 seconds Blind activated during 3 minutes USA Impulse control shorter than 0 5s Blind activated ...

Reviews: