Copyright © 2011 Somfy SAS. All rights reserved.
9
EN
Levixo 30-50 RTS
≥
22
3
m
m
1
2
4.7. Balancing the boom
Before performing any operations inside the
housing, it is essential to ensure that the spring
is released by moving the boom to the vertical
position.
- Unlock the boom (release key
in padlock open position
)
- Guide the boom until it is balanced.
- Loosen the locknut
1
.
- Tension or slacken the spring
2
until the boom remains
balanced at approximately 45°:
. if the boom seems to open, slacken the spring by
moving the tie-rod.
. if the boom seems to close, tension the spring by
moving the tie-rod.
- Tighten the locknut
1
.
- Lock the boom (release key
in padlock closed position ).
45 °
4.8. Wiring
4.8.1. General wiring diagram
- Ensure that the safety low voltage (230V) wires and safety extra low voltage wires are routed separately using
suitable cable glands and collars.
- The low voltage (230V) wires must be stripped, grouped and attached near the connectors so as to avoid
contact with terminals 7 to 20 in case of disconnection.
- Use double-insulated wires for the 230V supply.
- Install all the safety devices (photoelectric cells, safety edges, etc.) required to protect the zone from the
danger of crushing, movement force and cutting according to the applicable directives and technical standards.
If no directive or standard applies, inputs 9 and 10 must be bridged to terminal 7 if they are not used to connect
a safety device.
5
M
1
2
3
4
N
L
24V
0V
ST
OP
NC
PHOT
NC
ST
AR
T
NO
18
7
NC
SW
C
CO
M
NC
SW
O
8
9
11
12
14
15
13
10
16
17
19
20
terminals description
function
1
N
Neutral single-phase 230 V~, 50Hz power supply
2
L
Neutral single-phase 230 V~, 50Hz power supply
3-4-5
Motor connection (4 = shared, 3 and 5 = motor and capacitor)
1-4
230 V output, flashing orange light
7
COM
Shared by control inputs (8-9-10-11-12)
8
START
Control point input, sequential operation
9
STOP
Control point input (closing only)
10
PHOT
Photoelectric cell input
11
SWO
Opening end limit contact
12
SWC
Closing end limit contact
13-14
0V-24V~
Alternating 24 V output for power supply to the additional devices
15-16
Unused outputs
17
ANT
Aerial core
18
ANT
Aerial braid
19
COM
Shared
20
PED
Not used
When closing the boom, the setting spring must never be completely compressed. The minimum length that the
compressed spring can achieve with the boom in the horizontal position is 223 mm (see diagram opposite).
Summary of Contents for Home Motion LEVIXO 30 RTS
Page 1: ...FR Manuel d installation EN Installation instructions FA AR 5105360A LEVIXO 30 50 RTS ...
Page 2: ......
Page 18: ...16 Copyright 2011 Somfy SAS All rights reserved FR Levixo 30 50 RTS ...
Page 36: ...16 Copyright 2011 Somfy SAS All rights reserved EN Levixo 30 50 RTS ...
Page 41: ...Copyright 2011 Somfy SAS All rights reserved 16 Levixo 30 50 RTS FA ...
Page 59: ...AR Levixo 30 50 RTS Copyright 2011 Somfy SAS All rights reserved 16 ...
Page 75: ......