14
EN
Cell recognition by the motor electronics in sequential mode
►
RESET
30s
RESET
30s
RESET
30s
RESET
30s
RESET
30s
RESET
30s
RESET
30s
1
2
3
x3
[1].
Place a memorised 2 or 4 button remote
control on the target.
Press button 1 on the remote control
until the AUTO CLOSING indicator
flashes.
note:
Once step 1 has been carried out,
you can carry out the following steps
remotely (without placing the remote
control on the target).
[2].
Briefly press button 2
on the remote
control, the AUTO CLOSE indicator
will go out then flash.
[3].
Press button 1 on the remote control
3 times.
note:
in auto close mode, the cells are recognised by the motor’s electronics when auto close mode
is activated (see page 10)..
deleting cells
►
If you disconnect the cells:
- in sequential mode, repeat the procedure for cell recognition by the motor electronics in sequential
mode,
- in auto closing mode, repeat the activation procedure for the automatic closing mode on page 10.
Blocking cells
►
If the cells are blocked when closing the gate, the gate will stop and reverse its movement.
If the gate is closed and the cells are blocked, the gate will not open.
safety instructions
►
The correct operation of the cells must be checked every 6 months. To do this, when the gate is
closing, block one cell with your hand.
the gate should stop and open again
.