background image

4

EN

Affixing the label to the electronic unit

 

The label (20) should be affixed to the motor’s electronic unit (3).

switching the installation on

 

Switch the installation on.
The STATUS 

 indicator on the electronic unit will flash (2 pulses) to indicate that the motors are 

on and awaiting setting. 
If the STATUS   indicator stays out, see page 20.

Memorising a 2 or 4 button remote control

 

[1].

  Place the remote control to be memorised on the target.

[2].

  Briefly press the button on the remote control that will control the COMPLETE opening of 

your gate. 

 

>  The RADIO 

 indicator  will come on 

then go out when you release the button 

on the remote control.  

The button has been memorised.

Programming the gate travel

 

The motor's electronics automatically store:

 The motor torque required to control the 

• 

gate,  in  normal  operation.  Once  this  is 

stored, this enables any abnormal motor 

effort to be detected. 

 The travel distances required to fully open and 

• 

close  the  gate  with  the  positions  of  the  end 

stops.

During  programming,  you  should  remain  at  a 

normal distance from the gate and follow the steps 

below:

Press  button  1 

  on  the  remote  control 

to  initiate  a  coMPlEtE  opening/closing 

motion of the gate. 
the status indicator

   

of the electronic 

unit must be CONTINUOUSLY LIT.

If the STATUS indicator 

 is flashing, refer to 

the troubleshooting section on page 30.

The  gate  movements  must  not  be  interrupted 

(complete opening/closing). 

If they are interrupted, programming will resume the 

next time the opening command is made.

1

2

Quick coMMissioning

RESET

30s

RESET

30s

<0,5s

Button 1

Button 2

Summary of Contents for FREEVIA 600

Page 1: ...Freevia 280 290 300 600 FR Remplacement du bo tier lectronique EN Replacing the electronic unit 5072306A...

Page 2: ...1...

Page 3: ...sens du moteur intervertissez les fils branch s sur les bornes 9 et 10 Bleu Noir Marron Vert 9 10 M1 Bleu Noir Marron Vert 9 10 M1 Moteur gauche Vue de l int rieur Moteur droite Vue de l int rieur Ins...

Page 4: ...bo tier lectronique tiquette rouge 230 V V rifiez que les fils sont correctement bloqu s en tirant l g rement dessus Borne Fil bleu N 15 Fil rouge marron noir P 16 Fil vert et jaune Il est imp ratif d...

Page 5: ...nde La touche est m moris e Apprentissage de la course du portail L lectronique du moteur m morise automatiquement Le couple moteur n cessaire la commandeduportail enfonctionnement normal Cette m mori...

Page 6: ...s quentiel et en ouverture totale seule Montage du capot V rifiez que le moteur est verrouill 1 Placez le capot sur la bride embase du moteur 2 Mettez en place le joint 6 pour assurer l tanch it du m...

Page 7: ...n appui sur la touche 1 Ouverture totale du portail par un appui sur la touche 1 Ouverture partielle du portail environ 1 m par un appui sur la touche activ e Ouverture totale Ouverture pi tonne Ferme...

Page 8: ...e du portail par un appui sur la touche 1 Ouverture du portail par un appui sur la touche 1 Fermeture automatique du portail au bout de 30 secondes Maintien du portail en position ouverte par un appui...

Page 9: ...nde3touches Ouverture par un appui sur la touche Mont e Fermeture par un appui sur la touche Descente Arr t par un appui sur la touche centrale Note Les t l commandes ou points de commande 3 touches n...

Page 10: ...ommander d autres automatismes porte de garage volet roulant etc 2 touches 4 touches ou ou Ouverture Totale Ouverture Pi tonne si activ e Libre 1 1 2 2 3 4 1 2 CODE 3 4 1 2 CODE 3 4 1 2 CODE 3 4 1 2 C...

Page 11: ...cellules photo lectriques est install voir c blage page 13 Pour d sactiver le mode fermeture automatique et revenir en mode s quentiel r p tez l tape 1 ci dessus puis faites un appui bref sur la touch...

Page 12: ...ode 1 Posez une t l commande 2 ou 4 touches m moris e sur la cible Appuyez sur la touche 1 de la t l commande jusqu ce que le voyant FERMETURE AUTO clignote 2 Appuyez une fois sur la touche 1 de la t...

Page 13: ...fermeture du portail en cas de d tection d obstacle occultation des cellules Note Si le portail est ferm et que les cellules sont occult es le portail ne s ouvre pas Un jeu de cellules est constitu d...

Page 14: ...s cellules vous devez remettre le capot de la cellule mettrice mais pas celui de la cellule r ceptrice TX RX V rifiez le bon alignement des cellules Si le voyant de la cellule r ceptrice ne s allume p...

Page 15: ...r l lectronique du moteur au moment de l activation du mode fermeture automatique voir page 10 Suppression des cellules Si vous d branchez les cellules en mode s quentiel r p tez la proc dure de recon...

Page 16: ...commence clignoter 2 secondes avant la mise en mouvement du portail Installation du feu orange Le feu orange peut tre install de deux mani res voir fig 4a et 4b 3 4b 1 2 3 3 4a 5 10 9 8 11 6 6 mm 12...

Page 17: ...accorde directement au bo tier lectronique du moteur Pour augmenter l autonomie de la batterie en fonctionnement les accessoires filaires sont d sactiv s seuls les t l commandes et points de commande...

Page 18: ...er lectronique Cet accessoire est incompatible avec une alimentation solaire Raccordez l interphone aux bornes 3 et 4 tiquette jaune BUS du bo tier lectronique Note Sivoussouhaitezraccorderuninterphon...

Page 19: ...E V Raccordez T1 et C1 du digicode aux bornes 3 et 4 tiquette jaune BUS du bo tier lectronique V et V du digicode aux bornes 5 et 6 tiquette noire 24V du bo tier lectronique Une antenne d port e de pl...

Page 20: ...re les commandes filaires sont d sactiv es seuls les t l commandes et points de commande radio permettent de commander le portail 1 2 3 Ne branchez jamais votre moteur une alimentation 230 V pendant q...

Page 21: ...n veille Augmentez la luminosit environnante de votre bo tier lectronique avec une lampe torche par exemple si vous voulez r aliser des r glages Le voyant STATUT du bo tier lectronique clignote 1 impu...

Page 22: ...s 7 8 du bo tier lectronique V rifier le c blage du feu orange voir page 16 Court circuit moteur V rifiez le c blage moteur voir page 2 Le mode fermeture automatique ne s active pas le voyant FERMETUR...

Page 23: ...de la t l commande jusqu ce que le voyant RAZ MEMOIRE s allume Rel chez la touche 2 LevoyantSTATUTclignote Effacez les r glages Les r glages effac s sont la course des vantaux et l activation de la fe...

Page 24: ...commande LevoyantRAZMEMOIREclignote 3 Appuyez sur la touche 2 de la t l commande jusqu ce que tous les voyants s allument Rel chez la touche 2 LevoyantSTATUTclignote 3 1 2 x2 Effacez les r glages et...

Page 25: ...connected to terminals 9 and 10 Blue Black Brown Green 9 10 M1 Blue Black Brown Green 9 10 M1 Motor on left hand side View from inside Motor on right hand side View from inside Install the electronic...

Page 26: ...5 and 16 of the electronic unit red 230 V label Check that the wires are correctly secured in place by pulling them gently upwards Terminal Blue wire N 15 Red brown black wire L 16 Green and yellow wi...

Page 27: ...ing the gate travel The motor s electronics automatically store The motor torque required to control the gate in normal operation Once this is stored this enables any abnormal motor effort to be detec...

Page 28: ...mode opening automatically and at normal speed Fitting the cover Check that the motor is locked 1 Place the cover on the motor bracket base 2 Fit the gasket 6 to ensure that the motor is sealed and f...

Page 29: ...plete opening of the gate by pressing button 1 Open the gate completely by pressing button 1 Partial opening of the gate approx 1 m by pressing the activated button Complete opening Pedestrian opening...

Page 30: ...e is detected on closing the gate stops and opens fully Close the gate by pressing button 1 Open the gate by pressing button 1 The gate closes automatically after 30 seconds Hold the gate in the open...

Page 31: ...points The gate is opened by pressing the up button The gate is closed by pressing the down button The gate is stopped by pressing the central button Note Three button remote controls or control poin...

Page 32: ...ctions garage door roller blind etc 2 buttons 4 buttons or or Complete Opening Pedestrian Opening if activated Free 1 1 2 2 3 4 1 2 CODE 3 4 1 2 CODE 3 4 1 2 CODE 3 4 1 2 CODE Possible combinations fo...

Page 33: ...otoelectric cells is installed see wiring page 13 To deactivate automatic closing mode and return to sequential mode repeat step 1 above and briefly press button 2 on the remote control the AUTO CLOSE...

Page 34: ...r 4 button remote control on the target Press button 1 on the remote control until the AUTO CLOSING indicator flashes 2 Press button 1 on the remote control once The HIGH SPEED indicator will flash To...

Page 35: ...everse the closing movement of the gate when an obstacle is detected cells blocked Note If the gate is closed and the cells are blocked the gate will not open A set of cells comprises one transmitter...

Page 36: ...eck the cell alignment the transmitter cell cover must be fitted but not the receiver cell cover TX RX Check the correct alignment of the cells If the receiver cell indicator does not light up adjust...

Page 37: ...control 3 times Note in auto close mode the cells are recognised by the motor s electronics when auto close mode is activated see page 10 Deleting cells If you disconnect the cells in sequential mode...

Page 38: ...It starts to flash 2 seconds before the gate begins to move Installing the orange light There are two ways of installing the orange light see fig 4a and 4b 3 4b 1 2 3 3 4a 5 10 9 8 11 6 6 mm 12 mm 7...

Page 39: ...integrated and connected directly to the motor s electronic unit To increase the operation time of the battery during use the wired accessories are deactivated and the gate can only be controlled usi...

Page 40: ...the electronic unit This accessory is not compatible with solar power Connect the interphone to terminals 3 and 4 yellow BUS label on the electronic unit Note If you want to connect a different interp...

Page 41: ...1 of the digicode to terminals 3 and 4 yellow BUS label on the electronic unit V and V of the digicode to terminals 5 and 6 black 24V label on the electronic unit The aerial wire can be replaced with...

Page 42: ...tedusingsolarpower the wired controls are deactivated and the gate can only be controlled using the remote controls and the radio control points 1 2 3 Never connect your motor to a 230 V feed when it...

Page 43: ...utdoor lighting very low motor on standby Increase the light around the electronic unit using a torch for example if you want to make adjustments The STATUS indicator of the electronic unit is flashin...

Page 44: ...rt circuit of orange light terminals 7 8 on the electronic unit Check the wiring of the orange light see page 16 Motor short circuit Check the motor wiring see page 2 The automatic closing mode does n...

Page 45: ...TheMEMORYRESETindicatorflashes 3 Press button 2 on the remote control until the MEMORY RESET indicator comes on Release button 2 TheSTATUSindicator lashes Clear the settings The cleared settings are...

Page 46: ...rflashes 3 Press button 2 on the remote control until all the indicators come on Release button 2 TheSTATUSindicator flashes RESET 30s RESET 30s RESET 30s RESET 30s RESET 30s RESET 30s RESET 30s RESET...

Page 47: ......

Page 48: ...un appel local depuis un poste fixe Fax 04 50 96 71 20 E mail consommateur somfy com SOMFY UK Hotline 01 13 391 30 30 Somfy SAS dans un souci constant d volution et d am lioration peut modifier le pr...

Reviews: