Copyright © 2009-2011 Somfy SAS. All rights reserved.
Easy Sun io
10
EN
Observations
Possible causes
Solutions
The sun protection
applications (
«
Sun
»
group)
do not activate.
The Easy Sun io Sun function is
deactivated, and the applications
linked to the
«
Sun
»
group no longer
react automatically to variations in the
level of sunlight.
Activate the Sun function,
see the section
«
Operation in
automatic mode
»
.
The motors or receivers are paired
with a wind sensor and the wind
speed exceeds the set sensitivity
threshold: the
«
»
symbols are
displayed on the Easy Sun io.
Wait for the wind to drop. Refer
to the wind sensor's operating
guide.
The sunlight sensitivity threshold is
incorrectly set.
Readjust the threshold, see the
section
«
Adjusting the sunlight
sensitivity threshold
»
.
The Sensor box io is disconnected.
Check that the Sensor Box
io is properly connected, and
reconnect it if necessary.
The sun sensor is not operating.
See alert « ».
The
«
»
symbol appears
on the Easy Sun io screen.
The Easy Sun io batteries are low
Replace the batteries in the
Easy Sun io, see the section
«
Replacing the batteries
»
.
The Easy Sun io displays
the
«
»
(alert) and
« »
symbols (
«
Sun
»
group)
.
The sun sensor batteries are low.
See alert « ».
The Easy Sun io displays
the
«
»
symbol (alert).
The wind sensor batteries are low.
If several wind sensors are
paired to the Easy Sun io,
the information may only
refer to one wind sensor.
See alert « ».
List of possible alerts:
Symbol
Alert
Explanation
Local
The motor or receiver has been set to local mode from its local control
point. It is isolated from automatic control. Set it to automatic mode to
control it automatically using the Easy Sun io.
Radio
In manual mode: radio problem, the motor or receiver is not
responding. The motor or receiver may be out of range or have no
power supply.
In automatic mode: the Sensor box io is disconnected.
Obstacle
Stoppage at an obstacle: the application has encountered an obstacle.
If the obstacle is encountered during raising, give a lowering order to
clear the alert.
Heat
Motor in heat protection mode. After heavy use, the motor switches to
protection mode. Wait 15 minutes for the motor to cool.
Summary of Contents for Easy Sun io