13
EN
(1) Maximum load for motor to start and drive door for at least 5 cm (according to RAL-GZ definition)
171 min
63.6
140
125
Available travel: 2,555 / 3,155
Overall length: 3,295 / 3,895
Overall length: 3,153 / 3,753
65.
5
224.
4
224.4
Fixation: 2,982 / 3,582
Rail: 2,900 / 3,500
Rail : 2,900 / 3,500
33.
5
130.
9
404.2
404.
2
106
313.6
254.1
139.
5
164.
4
150.
1
112.2
TECHNICAL SPECIFICATIONS
Dexxo Pro 800 io
Dexxo Pro 1000 io
BASIC TECHNICAL CHARACTERISTICS
Mains supply
230 V - 50 Hz
Max. power consumption
Standby-Operation
5 W - 600 W (with 500 W remote lighting)
Traction force
Peak force
Starting force (1)
800 N
650 N
1000 N
800 N
Use
Number of Opening/Closing cycles per day
20 cycles max. per day with a standard rail - 50 cycles max. per day with a high performance rail
tested for 36,500 cycles with a standard rail and 90,000 cycles with a high performance rail
Max. speed
18 cm/s
Programming interface
7 buttons - 2 character LCD display
Operating temperature
- 20 ° C / + 60 ° C - indoor dry - IP 20
Travel end limits
Mechanical stopper at opening
Memorized end limit position at closing
Electrical insulation
Class 2: double insulation
Built in lighting
230 V / 40 W ; E14 socket
Somfy radio frequency
868 - 870 MHz
Number of channels that can be memorised
Situo io : 6 Others: unlimited
CONNECTIONS
Safety input
Type
Compatibility
Dry contact: NC
Photoelectric TX/RX cells - Reflex cell - Sensor strip with dry contact output
Pedestrian door safety input
Dry contact: NC
Wired control input
Dry contact: NO
Remote lighting output
230 V - 500 W - class 2
Orange light output
24 V - 15 W with built in flashing control
24 V controlled power supply output
Yes: for possible photoelectric TX/RX cell self-test
Safety input test output
Yes: for possible reflex cell or sensor strip self-test
Accessory power supply output
24 V - 500 mA max
Remote aerial input
Yes: io aerial compatible (Réf. 9013953)
Backup battery input
Autonomy
Yes: battery pack compatible (Réf. 9001001)
12 hours; 1 to 3 cycles depending on door
Charge time: 48 hours
OPERATION
Forced operation mode
By pressing and holding the motor control button
Lighting time delay (after movement)
Programmable : 60 s to 600 s
Automatic closing mode
Yes: programmable closing time delay from 10 to 120 s
Orange light pre-warning
Programmable: with or without prior warning (duration set to 2 s)
Safety input operation
While closing
Before opening
(Dangerous Movement Area Accessible
to the Public)
Programmable: Stop - Partial re-opening - Full reopening
Programmable: no effect or motion refused
Built-in obstacle detection
Adjustable sensitivity: 4 levels
Operation when an obstacle is detected
Programmable : partial re-opening or full reopening
Preset partial opening command
Yes can be selected: adjustable partial opening position
Progressive start up
Yes
Opening speed
Programmable from 3.5 cm/s to 18 cm/s: 10 possible values
Closing speed
Programmable from 3.5 cm/s to 18 cm/s: 10 possible values
Closure approach speed
Programmable: does not slow down, short slowdown zone (30 cm),
long slowdown zone (50 cm)
Troubleshooting
Recording and accessing data: Cycle counter, cycle counter with obstacle detection, number of
radio channels stored, history of the last ten defects recorded.
Dimensions