Risk of Injury
Only open and close the door if no person or obstacle is within the range of
movement of the door.
During a power failure of fault on the door drive open the door only by using the
internal or external emergency release mechanism. If, after operating the
emergency release the door is still difficult to operate call in a garage door
specialist.
Beware!
Do not expose handset to high temperatures (e.g. direct sunlight in vehicle)
■
Point hand set towards garage door and press keys 1-2 or
■
Operate button (e.g. Key button)
The drive light comes on for 60 seconds after opening or closing the door.
Operating Sequence
Open - Stop - Close - Stop - Open - Stop - Close - Stop etc
In case of emergency or loss of power the door can be uncoupled
from the drive and can be opened manually from the inside.
Risk of Injury
In the event of a power failure the open garage
door can drop down because the springs are
weak of broken or the door is not sufficiently
balanced.
■
Release door drive by pulling cord (a) The lever
engages and the door can be opened manually
■
Prepare door drive for coupling up by pushing
plastic lever (b) downwards. Finally move door to
out position Couple click, click
Operating Instructions
SOMFY Garage Door Drive AXORN 65/85
18
Internal
Emergency
Release
Garagentor öffnen,
schließen oder
stoppen