background image

SOMFY® is the leading global manufacturer of strong, quiet motors with electronic and app  

controls for interior window coverings and exterior solar protections. Over 270 million users  

worldwide enjoy the more than 170 million motors produced by Somfy. During the past 50 years,  

Somfy engineers have designed products for both the commercial and residential markets to  

motorize window coverings such as interior shades, wood blinds, draperies, awnings, rolling  

shutters, exterior solar screens and projection screens. Somfy motorization systems are easily  

integrated with security, HVAC and lighting systems providing total home or building automation.

FOR QUESTIONS OR ASSISTANCE PLEASE CONTACT TECHNICAL SUPPORT:

(800) 22-SOMFY (76639)
[email protected]

SOMFY SYSTEMS INC
SOMFY NORTH AMERICAN HEADQUARTERS

121 Herrod Blvd.
Dayton, NJ 08810
P:  (609) 395-1300
F:  (609) 395-1776

FLORIDA

1200 SW 35th Ave.
Boynton Beach, FL 33426
F:  (561) 995-7502

CALIFORNIA

15301 Barranca Parkway
Irvine, CA 92618-2201
F:  (949) 727-3775

SOMFY ULC
SOMFY Canada Division

5178 Everest Drive

Mississauga, Ontario L4W2R4 

P:  (905) 564-6446
F:  (905) 238-1491

www.somfypro.com

16 of 16

©

 S

om

fy 

Sys

tem

s,

 In

c.

 1

0/

20

20

. A

ll b

ra

nd

s,

 p

ro

du

cts 

an

d tra

dem

ark

are th

pro

perty 

of

 th

ei

r resp

ec

tiv

ow

ners.

PS-IG0 1

v.  1 .0

Summary of Contents for 1870272

Page 1: ...INTEGRATION GUIDE LUTRON INTEGRATION via SOMFY CONNECT UAI PLUS ...

Page 2: ...ING TO SYSTEM FOR OPERATION III LUTRON SYSTEM SETTINGS 5 NETWORK SETTINGS TELNET SETTINGS INTEGRATION SETTINGS IV UAI PLUS SYSTEM SETTINGS 8 CONNECTING TO UAI PLUS INTERFACE NETWORK INTEGRATION SETTINGS SDN INTEGRATION REPORT V INTEGRATION CONFIGURATION 11 LUTRON DEVICES ADDING LUTRON DEVICES COMMAND MAPPING LUTRON DEVICES TESTING VALIDATION BUTTON PROGRAMMING EXAMPLES LUTRON INTEGRATION via UAI P...

Page 3: ...Somfy Connect UAI Plus enables third party control from Lutron systems including HomeWorks QS RadioRA 2 RA2 Select GRAFIK Eye QS Quantum and myRoom Plus Platform Compatibility Lutron System Requirements GRAFIK Eye QS Yes QSE CI NWK E Caseta No RA2 Select Yes RR SEL REP2 BL RadioRA 2 Yes RR MAIN REP HomeWorks QS Yes HQP6 1or 2 Quantum Yes QSE CI NWK E myRoom Prime No myRoom Plus Yes GCU HOSP Vive N...

Page 4: ... of an SDN network Power is received through the SDN bus via a Bus Power Supply II INSTALLATION M O U N T I N G P O W E R W I R I N G T O S Y S T E M F O R O P E R A T I O N IP Integration a Connect Ethernet Port to the building IP network to which the 3rd Party System is also connected b Connect Port 2 to any SDN Device Port 4 of 16 ...

Page 5: ...AI Plus Ethernet Settings NOTE A Static IP Address is required to maintain Telnet connection III LUTRON SYSTEM SETTINGS L U T R O N N E T W O R K S E T T I N G S RA2 SELECT GRAFIK EYE QS QUANTUM MYROOM PLUS Network Settings will need to be configured upon initial setup and provided by the Lutron Integrator 5 of 16 ...

Page 6: ...ol app and the Somfy Connect UAI Plus application it is necessary to establish two separate Telnet channels for these two operations to occur L U T R O N T E L N E T S E T T I N G S RA2 SELECT GRAFIK EYE QS QUANTUM MYROOM PLUS Telnet Settings will need to be configured upon initial setup and provided by the Lutron Integrator RADIO RA2 NOTE RA2 Select is limited to only one Telnet connection 6 of 1...

Page 7: ...bled for integration All required devices should be confirmed enabled by the Lutron Integrator GRAFIK EYE QS QUANTUM MYROOM PLUS Integration Settings will need to be configured upon initial setup and provided by the Lutron Integrator RA2 SELECT RA2 Select integration can only be enabled for the entire system and not individual devices 7 of 16 ...

Page 8: ...click the Network folder Note If prompted that network discovery is turned off click OK Right click on the top bar then choose Turn on network discovery and file sharing In the following window double click No make the network that I am connected to a private network 4 The UAI Plus icon will appear in the list of devices which means it is now connected Double click the UAI Plus icon in the device ...

Page 9: ...ETTINGS 1 Select the Lutron System from SYSTEM dropdown 2 Enter Lutron IP Address in the ADAPTOR_IP field 3 Select ENABLE from the CONNECTION dropdown 4 Enter Telnet Login Username in the LOGIN field 5 Enter Telnet Login Passphrase in the PASSWORD field within a few moments the login will take place Open the Lutron tab to enter the Lutron Settings Properties page NOTE Prior to integration confirmt...

Page 10: ...rt hover over the SDN tab then click Report The Integration Report is downloaded as a csv file and viewed in Excel 10 of 16 The Integration Report lists the available group addresses required for Lutron integration The Group Name is selected when command mapping Lutron devices ...

Page 11: ...identifier which can not be changed in the Somfy Connect UAI Plus BUTTON The specific keypad button timeclock event occupancy sensor and other devices COMMAND Actions of each stage of a button press Press Release Release for Hold Hold Multi DEVICE TYPE DEVICE ID BUTTON COMMAND Keypad Variable Refer to keypad selection chart 3 Press 4 Release 5 Release for hold 6 Hold Multi Timeclock Variable 5 Eve...

Page 12: ...numbers and their text Only the device ID is represented in the integration guide Refer to the Lutron Integrator for the event number NOTE The Lutron Integration Report should be provided by the Lutron Integrator There is no Integration Report available for GRAFIK Eye QS so the functions of the buttons must be provided by the Lutron Integrator 1 In the Lutron Devices tab select the Plus Sign for f...

Page 13: ...tton Programming LED not used KEY Group Keypad Programming 8 Select the SDN COMMAND from the dropdown CLOSE Sends the motor group to the closed or 100 position OPEN Sends the motor group to the open or 0 Position STOP Stops the motor group when moving RECALL Sends a motor group to specified intermediate position 1 16 to be entered in the Value column in the Lutron table STORE Records a specific mo...

Page 14: ...RM LUTRON BUTTON ID BUTTON AND ACTION With the Telnet tab open make the physical button press to view the device information Reference this information to what is entered in the Lutron table VALIDATION Test all keypad button presses to confirm proper functionality To test timeclock functions refer to the Lutron Integrator to emulate command from Lutron terminal 14 of 16 ...

Page 15: ... b Right click in the Command column then select OPEN c Click the Copy button to create an identical map below d Edit the Lutron ID and change the Command column from OPEN to CLOSE Group Control a Right click in the Device column then select KEY repeat this step for each group button and be sure to change the Button ID each time b Enter SDN Group Address repeat this step for each group button Mome...

Page 16: ...n systems are easily integrated with security HVAC and lighting systems providing total home or building automation FOR QUESTIONS OR ASSISTANCE PLEASE CONTACT TECHNICAL SUPPORT 800 22 SOMFY 76639 technicalsupport_us somfy com SOMFY SYSTEMS INC SOMFY NORTH AMERICAN HEADQUARTERS 121 Herrod Blvd Dayton NJ 08810 P 609 395 1300 F 609 395 1776 FLORIDA 1200 SW 35th Ave Boynton Beach FL 33426 F 561 995 75...

Reviews: